11
RESET of the regulator
MASTER RESET of the regulator
Special situations
Pressing the
RESET button
( ) causes the time and day setting to be erased, and the
regulator to be restarted.
The MASTER RESET function restarts the regulator and restores factory settings. This
function is invoked by pressing the and RESET buttons simultaneously.
NOTE: All user-defined programs will be erased!
•
When 3 consecutive transmissions (after 15 minutes) from the AURATON R25 RT
regulator and/or the T-2 thermometer are lost, an error is signalled on the RT receiver
(LED flashing continuously red and green). The RT receiver starts executing the ON
- OFF cycle memorised during the last 24 hours of operation until the problem is
removed.
•
When both signals return (from the AURATON R25 RT regulator and the T-2
thermometer), the error is cancelled and the receiver enters its normal mode of
operation.
•
When only the T-2 thermometer signal returns, the receiver uses the last memorised
setpoint value and maintains it while signalling the error.
•
When the H-1 handles, the T-2 thermometer and the AURATON R25 RT regulator (the
temperature is measured with the T-2 thermometer) are paired with the receiver,
then maintaining the work cycle from the last 24 hours occurs only after losing the
signal from the T-2 thermometer. When only the signal from the AURATON R25 RT is
missing, the RT receiver automatically maintains the last memorised setpoint from the
AURATON R25 RT regulator and also signals an error.
•
When you have only the H-1 handles and the T-2 thermometer paired with the RT
receiver without the AURATON R25 RT regulator, the RT receiver maintains a constant,
factory-defined temperature of 20°C. If you pivot any window equipped with the H-1
handle paired with the receiver, a temperature of 17°C is maintained. If you open
any window equipped with the H-1 handle paired with the RT receiver, the receiver
switches off the heating device, but will switch it back on when the temperature falls
below 7°C.