background image

VI SPECIFICATIONS

Physical Characteristics 

Size

98(W)X 28(L)X 73(H) mm 

Material   Polycarbonate (PC) 
Weight 98g (battery not included)

Electrical Characteristics

Power Source

AAA 1.5V Alkaline battery x 2

Switching Relay: 
Resistive load

5A at 250VAC 

Inductive load

3A at 250VAC 

Temperature Measuremen

 0 - 40°C 

Temperature Accuracy

±1.0°C 

Temperature Control

5 - 35°C 

Temperature Control Span

±0.5°C 

Output On Delay

20 seconds 

Operating Temperature

-10°C to 50°C (non-condensing) 

Storage Temperature

 -30°C to 60°C 

Operating polluted condition Normal 

Summary of Contents for 1300

Page 1: ...USER S MANUAL AURATON 1300 I INTRODUCTION This thermostat is designed to be used with electric gas or oil heating system Appearance LCD ...

Page 2: ...e thermostat should be installed at an inside wall with freely circulating air Find a place where your family usually occupied Avoid close to some heat generating appliance e g TV heater refrigerator or exposed to direct sun light Do not install near a door where the thermostat will suffer from vibration For optimal operation choose a mounting location About 1 5 meter above the floor in an area wi...

Page 3: ...TON 1300 thermostat can be used with single stage heating system Inside the thermostat three terminals which label COM common NC normal close and NO normal open would be found In most case COM and NO are used Temperature Span Span is the temperature difference between the turn ON and OFF temperature The factory pre set span is 0 5 C For example control temperature setting is 20 C The heater will b...

Page 4: ...gently push the reset button TEMPERATURE 22 C CONTROL TEMPERATURE 20 C OUTPUT OFF III CONTROL TEMPERATURE At the normal operation mode the temperature could be set Push button to view the setting temperaturewhich was set last time When power up or reset the factory preset control temperature 20 C is shown Hold button about 3 seconds and the temperature indicator will flash one time Push button to ...

Page 5: ...age of the battery decrease to certain level the LCD will be blank In this case the batteries should be changed as soon as possible to avoid any data loss V HEATER OPERATION Heater On Operation The heater will be turned on when the room temperature is lower than the programmed temperature and the Heater On Icon will be displayed as shown Output On Delay For safety purposes the thermostat has an au...

Page 6: ...rce AAA 1 5V Alkaline battery x 2 Switching Relay Resistive load 5A at 250VAC Inductive load 3A at 250VAC Temperature Measuremen 0 40 C Temperature Accuracy 1 0 C Temperature Control 5 35 C Temperature Control Span 0 5 C Output On Delay 20 seconds Operating Temperature 10 C to 50 C non condensing Storage Temperature 30 C to 60 C Operating polluted condition Normal ...

Reviews: