AMMF16R

 

 

 

 

 

A screw driver is needed for assembly.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Ensure that the power cord is disconnected from the power outlet.

 

2. Align misting fan pole to the base hole to the front direction of the base.    Gently push the hose and     

power cable of the air pump aside and press the mist fan pole until the screw hole is aligned. (fig. 1). 
Make sure you do not 

kink

 the hose in this process. 

3. Fasten the misting fan pole assembly to the power base assembly with the two screws (fig.1). 
4. Fasten the misting fan pole assembly to the power base assembly with the pole screw (fig.2). 
5. Loosen the pole lock knob and pull the inner pole out. Tighten the lock knob and attach the mist fan 

assembly to the inner center pole and fasten screw knob (fig. 3). 

6.  Disassemble  the  rear  misting  fan  guard  nut

  (rotate  counterclockwise)

  and  the  misting  fan  blade  nut 

(rotate clockwise) 

from the misting fan head assembly (fig.4). 

7. Align the rear fan guard hole to the three pins on the motor housing, and fasten the rear fan guard to 

the fan head assembly with the rear fan guard nut (figure 5).   

8. Mount the fan blade to the fan motor shaft (fig.6).    Make sure the fan blade gap aligns with the pin clip   
on the motor shaft and then screw on the blade nut (fig.7). Mount the front guard and tighten all the hinges 
around outer rims of the fan guard (figures 8 & 9).   
9.  Connect  nozzle  housing  by  gently  sliding  the  nozzle  housing  into  the  holder  on  the  front  fan  guard 

(fig.10) 

10. Connect the air and water tubes to the connectors on the misting fan pole assembly. The water is the   

smaller tube. Make sure the tube is pushed all the way into the connector, and then make the electrical   
connection (fig.11) 
 
 
 

General Assembly Instructions 

Formatted:

 Indent: First line:  0 ch

Deleted: 

kinked

Deleted: 

  ¶

Summary of Contents for AMMF16R

Page 1: ...SE INSTRUCTIONS CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions call 1 800 320 6478 or go to www auramist net ...

Page 2: ...misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or killed WARNIN...

Page 3: ...been dropped or damaged left outdoors or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS PROPERLY GROUNDED DO NOT MODIFY THE PLUG PROVIDED WITH THE MISTIN...

Page 4: ... fan on a stable flat surface to avoid the chance of tipping 23 Never place the misting fan where it may fall into a water reservoir example bathtub or pool or anything containing an electrical conductive substance 24 When the product is used outdoors use only on GFCI Ground Fault Circuit Interrupter protected receptacles 25 This product must be grounded If it should malfunction or break down grou...

Page 5: ...uard assembly 1 2 Rear fan guard 1 3 Rear fan guard nut screw on motor housing 1 4 Fan blade 1 5 Fan blade nut screw on motor axis 1 6 Power base assembly 1 7 Fan head assembly 1 8 Fan pole assembly 1 9 Fan pole screw 1 10 Screws 2 Carton Contents ...

Page 6: ...an guard nut rotate counterclockwise and the misting fan blade nut rotate clockwise from the misting fan head assembly fig 4 7 Align the rear fan guard hole to the three pins on the motor housing and fasten the rear fan guard to the fan head assembly with the rear fan guard nut figure 5 8 Mount the fan blade to the fan motor shaft fig 6 Make sure the fan blade gap aligns with the pin clip on the m...

Page 7: ...ALLY PLUGGED TO THE POWER OUTLET 2 Fan Operation ON OFF Speed control Press the button to Low Medium High or OFF to select fan speed fig 1 3 Fan Operation Oscillation Control To operate the oscillation function press down the oscillation switch To stop the oscillation function pull up the oscillation switch The oscillation angle is approximately 65 degrees fig 2 4 Misting Operation IMPORTANT This ...

Page 8: ...4 Misting ON OFF control Mist ON Press the rocker switch to the ON position fig 5 Turn the ball valve to the ON position fig 6 Open the flow control valve until mist is visible then refer to ADJUSTING MIST DENSITY section to get an optimal mist performance fig 7 Mist OFF Turn the ball valve to OFF position fig 8 To prevent the accumulation of mineral deposits let the pump run for 2 minutes after c...

Page 9: ...ockwise fig 11 5 Operating Tips For dry climates increasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended CUSTOMER RESPONSIBILITIES Read and follow the maintenance schedule and the maintenance procedures listed in this section WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE MOVING OR SERVICING THE MISTING FAN WARNING DO NOT IMMERSE THE MISTI...

Page 10: ...filter from package and orient the directional arrow so that the flow direction is towards the left fig 3 Push the hose into the push in connector to connect the filters Reinstall filter cover FUSE REPLACEMENT WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE REPLACE THE FUSE CAUTION This product employs overload protection fuse A blown fuse indicates an overload or short circuit situation If the fuse ...

Page 11: ...ter faucet is OFF 2 Ball valve is OFF 3 Misting valve in the CLOSED position 4 Water filter needs to be replaced 1 Open the water faucet 2 Switch the ball valve to ON position 3 Open valve counterclockwise 4 Replace water filter Water streaming from nozzle 1 Air pump is not working 2 Air flow is lower 3 Air filter needs replacement 4 Air hose leaks 5 Foreign object in nozzle 1 Turn on the mist ON ...

Page 12: ...Rev A 07 10 AMMF16R 12 Exploded View ...

Page 13: ...er 1 11 FV9144 70 10 ball valve 1 12 ZF01MF A0 02 base plate asm 1 13 ZF01MF 30 00 pump vibrate resistant 4 14 WZQB01 00 00 air pump 1 15 ZF01MF 20 00 fan pole asm 1 16 ZF01MF A0 03 fan head asm 1 17 ZF01MF 10 03 rear guard grill 1 18 ZF01MF 10 22 rear grill nut 1 19 ZF01MF 10 02 fan blade 1 20 ZF01MF 10 21 blade nut 1 21 ZF01MF 10 01 front guard grill 1 22 TODQ56 05 01 5A fuse 1 23 FV9144 00 03 n...

Page 14: ...r you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes AuraMIST LLC 5210 Village Parkway Rogers AR 72758 The model number and manufacturing date co...