READ AND SAVE THESE INSTRUCTIONS 

CAUTION: 

Before using this product read this manual and follow all safety rules and 
operating instructions.  Failure to comply with instructions will void the warranty 
and could result in personal injury and/or property damage.

 

 

IMPORTANT: 

For replacement parts or assembly questions call 1-800-320-6478 or go to 

www.auramist.net

  

 

TABLE OF CONTENTS 

1.  Safety Information…………………… 1 
2.  Hardware Package Contents………. 2 
3.  Carton Contents……………………... 3 
4.  Assembly……………………………... 3 
5.  Operation…………………………….. 6 
6.  Maintenance…………………………. 7 
7.  Storage……………………………….. 8 
8.  Troubleshooting……………………… 8 
9.  Warranty…………………………….... 8 

 

SAFETY INFORMATION 

 

1. 

Read all instructions before using the Misting Fan. 
This product is designed to operate with 

DRINKING WATER ONLY

.  City water supply, 

bottled water, and other sources deemed suitable 
for human consumption will ensure optimal 
functionality of the system throughout 
maintenance intervals. In the event that another 
liquid other than DRINKING WATER is used to fill 
the water tank, immediately drain the contents of 
the tank and contact customer service regarding 
steps to take to help determine the usability of 
your system.

 

2. 

Make sure that the power source complies with 
the electrical requirements of the Misting Fan. 

3. 

Use this Misting Fan only as described in this 
manual.  Any other use may cause electrical 
shock, fire, injury to persons or animals and may 
void the warranty. 

4. 

To reduce the risk, of personal injury, the misting 
fan should not be used as a toy or placed where 
small children can reach it. 

 

WARNING:

 DO NOT USE THE FAN MOTOR 

OR THE MISTING ON-OFF SWITCHES AS THE 
MEANS OF DISCONNECTING POWER WHEN 
INSTALLING OR SERVICING THIS PRODUCT.  
ALWAYS DISCONNECT THE POWER CORD. 

 
5. 

Disconnect the power cord before moving or 
performing any maintenance on the Misting Fan. 

6. 

This Misting Fan shall not be used in potentially 
dangerous conditions, such as flammable, 
explosive or chemically loaded environments. 

7. 

The Misting Fan shall be completely assembled, 
according to these instructions before connecting 
to a power source. 

 

WARNING:

 DO NOT USE A THREE PRONG TO 

TWO PRONG ADAPTER.  IMPROPER 
CONNECTION MAY CREATE A RISK FOR 
ELECTRICAL SHOCK. 

 
8. 

The power cord of the Misting Fan is equipped 
with a three prong grounded plug, and it shall be 
connected into the corresponding power 
receptacle.  Under no circumstance, shall the 
grounding leg be removed or bypassed from the 
power cord plug. 

9. 

If the use of an extension cord is required, 
minimize the risk of overheating or fire by ensuring 
the extension cord is UL, ETL, CETL or CSA 
listed.  Do not operate more than one Misting Fan 
per extension cord. 

10.  Do not operate the Misting Fan with a damaged 

power cord, plug or after the Misting Fan is 
damage in any manner.  Call an authorized 
service center for evaluation, adjustment or repair. 

11.  Do not insert or allow any foreign objects to enter 

the intake or exhaust air openings, as it may 
cause mechanical, electrical, or fire damage to the 
Misting Fan. 

12.  Do not block or tamper with the Misting Fan 

nozzles, as it may reduce or impede the 
functionality or quality of the Misting Fan. Call an 
authorized service center for evaluation, 
adjustment or repair. 

13.  Always place the Misting Fan on a stable flat 

surface to avoid the chance of tipping over the 
Misting Fan. 

14.  Never placed the Misting Fan where it may fall into 

a water reservoir (example: bathtub, pool), or 
anything containing an electrical conductive 
substance. 

15.  When the product is used outdoors, use only on   

GFCI (Ground Fault Circuit Interrupter) protected 
receptacles.  
 

CAUTION:

 THIS MISTING FAN SHALL BE 

ASSEMBLED ACCORDING TO THESE 
INSTRUCTIONS, DUE TO ITS WEIGHT AND 
SIZE.  FAILURE TO DO SO COULD RESULT IN 
THE PRODUCT COMING APART DURING 
OPERATION AND/OR PERSONAL INJURY.

 

Summary of Contents for AM11MF30-1

Page 1: ...y maintenance on the Misting Fan 6 This Misting Fan shall not be used in potentially dangerous conditions such as flammable explosive or chemically loaded environments 7 The Misting Fan shall be completely assembled according to these instructions before connecting to a power source WARNING DO NOT USE A THREE PRONG TO TWO PRONG ADAPTER IMPROPER CONNECTION MAY CREATE A RISK FOR ELECTRICAL SHOCK 8 T...

Page 2: ... mm Pressure Washer C 1 4 8 mm Flat Washer D 2 1 Electrical Enclosure Top E 2 2 ST 3 5 x 14 Screw F 2 1 Electrical Enclosure Bottom G 3 2 ST 4 0 x 12 Screw H 4 2 ST 3 0 X 14 I 5 1 Electrical Box Lid J 5 1 Electrical Enclosure K 5 2 ST 3 5 x 10 Screw All parts of this appliance are packed in one carton A B C D F E G H I J K ...

Page 3: ...0 Manual FAN POLE ASSEMBLY TO POWER BASE ASSEMBLY 1 Align fan pole assembly OFF MIST PRIME switch to the Ventilation Grill Gently pull hoses from power base assembly A 1 A 1 2 Fasten four places the fan pole assembly to the power base assembly by using fasteners from bag 1 A 2 A 2 3 Fasten electrical housing with 2 screws from bag 2 B 1 B 1 1 2 4 3 5 6 8 OFF MIST PRIME switch SWITCH Ventilation gr...

Page 4: ...g full you should feel two clicks C 3 Failure to do so could result in a leaky connection To remove the hose slide the hose out of the fitting while pushing the plastic ring on the fitting in C 4 FAN POLE ASSEMBLY TO MOTOR ASSEMBLY 1 Attach motor to the Center Pole and fasten securely D 1 Remove the two screws pre installed on the top of the Fan Pole align the Fan Motor on the pole with the mounti...

Page 5: ...s of the fan guard E 3 E 4 E 2 E 3 3 Place the small screw and nut at the bottom hole to secure the forward and rear guards E 4 E 4 4 Connect nozzle housing by gently pushing the attachment legs on the front guard wire E 5 E 5 AIR WATER AND ELECTRICAL CONNECTIONS 1 Connect the air and water tubes to the connectors on the Mist Control Fan Pole Assembly The water is the smaller tube Make sure the tu...

Page 6: ... to operate with DRINKING WATER ONLY Fan and or misting system may start up when the unit is initially plugged to the power outlet BEFORE STARTING Remove fill cap on power base assembly and fill with DRINKING WATER through the basket filter until tank is filled to approximately 1 below the bottom of the basket filter Add teaspoon of unscented chlorine bleach to the water tank approximately 5 drops...

Page 7: ... turning clockwise CLEANING BASKET FILTER Remove fill cap and remove basket filter Rinse debris from filter with running water Replace basket filter and fill cap CONDITIONING WATER TANK Conditioning the water tank ensures that the cooling system will operate at optimal levels throughout the life of the system It is suggested that the tank be conditioned at an interval of every 4th filling or once ...

Page 8: ...le 1 Replace air filter 2 Turn off fan motor and feel any air leaks on hoses 3 Order and replace nozzle holder Water dripping from drain plug 1 Drain plug not seated 2 Drain plug seal is missing or damage 1 Properly seat drain plug 2 Replace drain plug seal SAFETY WARRANTY WARRANTY ONE YEAR FULL WARRANTY This product is warranted for one year from the date of purchase against defects in materials ...