3.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a washer and a screw [4]. Thereby, ensure that dimensions
X, Y or L are observed (refer to figure and table <Mounting positions for cou-
pling>).
Figure 9: Examples: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
[4]
Screw with washer
Figure 10: Mounting positions for coupling
Table 6:
FQM 12.1
FQM 10.1
FQM 07.1
FQM 05.1
Dimensions in
[mm]
FA14
FA12
FA12
FA10
FA10
FA07
FA07
MSS SP-101
0.24 [6]
0.24 [6]
0.24 [6]
0.24 [6]
0.20 [5]
0.20 [5[
0.20 [5]
X max.
0.39 [10]
0.39 [10]
0.39 [10]
0.39 [10]
0.20 [5]
0.20 [5]
0.20 [5]
Y max.
0.39 [10]
2.36 [60]
2.36 [60]
0.39 [10]
1.77 [45]
1.77 [45]
1.77 [45]
L max.
4.
Apply non-acidic grease at splines of coupling (e.g. Gleitmo by Fuchs).