3.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a washer and a screw [4]. Thereby, ensure that dimensions
X, Y or L are observed (refer to figure and table <Mounting positions for coup-
ling>).
Figure 10: Examples: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
[4]
Screw with washer
Figure 11: Mounting positions for coupling
Table 6:
FQM 12.1
FQM 10.1
FQM 07.1
FQM 05.1
Dimensions
[mm]
F14
F12
F12
F10
F10
F07
F07
EN ISO 5211
6
6
6
6
5
5
5
X max.
10
10
10
10
5
5
5
Y max.
100
60
60
100
45
45
45
L max.
4.
Apply non-acidic grease at splines of coupling (e.g. Gleitmo by Fuchs).