Commissioning
30
COMfortel WS-400 IP - Setup V04 02/2016
2.
Select one of the following options from the
Method
list field
displayed under
IPv4
:
쐽
Use Static IP Address
: The IP DECT server is assigned
a fixed IP address (recommended).
쐽
DHCP assigned
: The IP DECT server gets its IP address
automatically from a DHCP server.
3.
Only for
Use Static IP address
:
쐽
Enter the IP DECT server‘s IP address in the
IP addr
entry field.
쐽
Enter the network mask in the
Netmask
entry field.
쐽
Enter the gateway name in the
Gateway
entry field.
4.
Under
NTP
, enter the NTP server's IP address in the
Server
entry field.
5.
Select the time zone from the
Time zone
list field.
6.
Click
Save > OK > Reboot now > OK
.
Security Settings
1.
Open the
Configuration > Security
page.
2.
Enter the current password in the
Current Password
entry
field.
3.
Enter a new user name in the
New username
entry field.
4.
Enter a new password in the
New password
entry field.
5.
Then enter the new password again in the
New password
again
entry field.
6.
Click
Save > OK
.
SIP Settings
–
Knowledge of the DECT handset data:
쐽
Internal number, password (entered in the PBX)
1.
Open the
Configuration > SIP
page.
2.
Under
General
, enter the number of the SIP port in the
Local
port
entry field.
Note:
The standard port 5060 is already set up. Configure the
port according to the port configuration in the PBX.
3.
Enter the PBX's IP address in the
Default domain
entry
field.
4.
Select the codec priority in the
Codec priority
list fields.