Commissioning
COMfortel WS-400 IP - Setup V04 02/2016
29
The LED on the front cover flashes red followed by a
steady green if the IP DECT server has started.
Opening the Configuration Manager
Requirements
–
Network connection between the PC and the IP DECT server
–
Knowledge of the IP DECT server's IP address
Note:
If a DHCP server is set up in the local network, the IP DECT
server will get its IP address from this DHCP server. You can
determine the IP addresses either via the DHCP server and the
IP DECT server's MAC address or via UPnP.
If no DHCP server has been set up, the static IP address
192.168.0.1 and the network mask 255.255.255.0 are used
instead after a waiting time of approx. 1.5 minutes.
–
Knowledge of the access data (see chapter Commissioning
> Default settings when the equipment is supplied).
1.
Start a browser (e.g. Mozilla Firefox).
2.
Enter the IP DECT server's IP address (e.g.
http://
192.168.0.1
) in the browser's address bar.
3.
Enter the user name in the
User name
entry field.
4.
Enter the password in the
Password
entry field.
5.
Click
OK
.
Configuring the IP DECT Server
Requirements
–
PBX with the following features:
쐽
available internal VoIP channels
쐽
configured internal SIP subscribers (telephone number,
user name, PIN/password)
Network settings
1.
Open the
Configuration > General
page.