4.2 - Installer Menu
4.2.1 - Choice of
backup
corresponding to the
installation
b a c k u p
H P o n l y
H P + b o i l e r
h p + e l e c t .
b o i l e r
e l e c t r i c
Enter
Enter
Enter
Enter
Enter
The installer menu allows access to the following settings :
-
backup
-
data calc.
-
config
-
counters
-
settings
-
forcing
-
display
-
reset para
The installer menu allows to consult the data measured from settings:
- measured values
- target calculations
- timeouts
- counters
Accessing the installer menu:
• Press
• Turn the dial until «
inst. menu.
» is displayed
• Press
and
buttons
simultaneously.
•
Keep them held down simultaneously
for 3 seconds.
• Access to choice of appliance
authorised to operate
Operation using the Heat Pump
only, no back-up (by default)
Operation using the Heat Pump
with an existing back-up boiler to
ensure radiator circuit (or underfloor
heating circuit) heating only.
Operation using the Heat Pump with
the integrated 6kW electrical back-
up to ensure heating of DHW only.
In this case, manually force the
back-up boiler to ensure heating of
the radiator (or underfloor heating)
circuit.
Back-up operation using only
the existing boiler (for temporary
forcing) to ensure the heating of
the radiator circuit. (or underfloor
heating circuit) exclusively.
Back-up operation using only the
integrated 6kW electrical back-up
(for temporary forcing) to ensure
the heating of DHW exclusively. In
this case it is necessary to manually
force the back-up boiler so as to ensure
the heating of the radiator circuit (or
underfloor heating circuit).
C O N F I G U R .
When the choice of «
hp + ELEC.
» or «
ELECTRIc.
» is given, these two
warning screens are displayed:
then
S E C T I O N
C A B L E O K
n o
C A B L E O K
n o
C A B L E O K
y e s
These screens are to remind you that you are putting into
operation the electrical back-up and serves as an alert.
The selected choice is only activated when the choice is confirmed.
Is the electricity supply cable of the HRC
70
Pilot sufficient?
Check § «Connecting the HRC
70
Pilot to the power
supply» based on the voltage supplied, that
the power cable section can support the power
output of the appliance.
Press on the dial to access the
HRC
70
Heat Pump
selection
The «
Configuration
» sub-menu allows the selection of the
Heat Pump model, as well as the type of circuit and type of
control installed. The specific settings for each configuration are
automatically adjusted by the regulation module.
See the Hydraulic schematic diagrams in the Appendix.
4.2.2 -
Configuration
of the HRC
70
Heat Pump
and of the circuits
4.2.2.1 - Heat Pump model
Enter
Select the Heat Pump model installed.
The different Heat Pump models appear on the display in the
following order :
HRC
70
- 17 / HRC
70
- 25 / HRC
70
- 20 / HRC
70
- 35 /
HRC
70
- 7 / HRC
70
- 11 -
h r c 7 0
-
1 7
h p
h r c 7 0
-
7
h p
Press to confirm the choice of
HRC
70
17kW Heat Pump
Press to confirm the choice of
HRC
70
Heat Pump (7kW in this
example)
Turn the dial to select an HRC
70
Heat Pump
with a power of 25 - 20 - 35 - 7 or 11 kW
Enter
Enter
Example