Audison LRX6SR User Manual Download Page 14

ACCESSORIES

34

This cooling system is specially designed to provide LRx amplifiers with the right working temperature.
CLK2 should be used when LRx amplifiers work in extremely hard conditions (very low loads) or in
installations where space is too narrow and heat sink cooling is not enough. It consists of two units to
apply onto the amplifier sides; each of them is provided with an electronically controlled fan. Its
intervention depends on a thermal sensor that starts the system as soon as LRx heat sink reaches 45°C.
The same sensor is connected to a special circuit which controls the two fans speed progressive
increase when temperature increases, too.
Air flux constant control allows the amplifier very good thermal stabilization and limits noise.

CLK2 – LRx Cooling Kit

Man. LRx 6.SR in 4 Lingue  10-02-2004  16:56  Pagina 34

Summary of Contents for LRX6SR

Page 1: ...CAR POWER AMPLIFIER ...

Page 2: ...ry positive terminal connect one end of the power supply cable to it after connecting its other end to the amplifier The fuse value mustbe the same as the amplifier built in one In case the cable supplies several amplifiers the fuse value will have to beequal to the sum of the values of all other fuses in the system For safer driving we recommend to adjust volume not to drown external traffic soun...

Page 3: ...fication 31 VCA VCA1D modules insertion 31 Technical features Size for fixing 32 LRx 6 SR Direct 32 Accessories VCRAK and VCRDK 33 CLK2 LRx Cooling Kit 34 Configurations Block diagram 35 Controls panel diagram and subsonic filter switch 36 Configuration example Front Rear Center Sub 36 Installation Logo rotation 37 Amplifier fixing 38 Electric connections 38 audison cable products for electric con...

Page 4: ... realise systems designed to attain outstanding musical features and very high sound pressures SPL LRx 6 SR Direct has a bypass subsonic filter 24dB Oct with adjustable frequency pre set at 20Hz In case LRx amplifiers are used in extremely difficult conditions very low loads or in installations where space is too narrow and their heat sink cooling is not enough they can be employed together with C...

Page 5: ...25 IN OUT PANEL FUNCTIONS ...

Page 6: ...26 POWER SUPPLY PANEL FUNCTIONS ...

Page 7: ...parent cover 3 Check the value of the new fuse to assemble then fix it by gradually and alternately fastening the two screws This will avoid voltage drops along the line and will make the device perfect functioning easier 2 Remove the screws which fasten the fuse to eliminate pieces of the broken one prevent them from going into the device FUSE REPLACEMENT ...

Page 8: ...28 CONTROLS PANEL FUNCTIONS AND CONTROLS ...

Page 9: ...29 CONTROLS PANEL ...

Page 10: ...heard by human ears but cause useless and damaging stress to amplifier and speakers When it is on ON frequencies below the chosen cut off one are eliminated Subsonic filter cut off frequency can be adjusted through 4 Hz steps this occurs by replacing the special resistors located into a socket which can be reached through the setting panel in the amplifier bottom The amplifier is given with 20 Hz ...

Page 11: ... LRx 6 SR Direct can accept one of the two optional kits which allow the subwoofer volume remote control VCRAK or VCRDK These kits have a specific module VCA or VCA1D to insert into the amplifier through the setting panel Installation 1 Remove BYP12 bridge 2 Insert VCA VCA1D module Insertion key It prevents the module from being inserted in the wrong way Subsonic filter is pre adjusted at 20 Hz In...

Page 12: ...40 Input sensitivity 0 2 5 VRMS Input impedance 15 kOhms Load impedance Front Rear Center Sub 4 2 Ohms Nominal output power RMS NP 12VDC THD 0 3 55W x 5 4 Ohms 150W x 1 4 Ohms Output power RMS 13 8 VDC THD 1 A config 55W x 5 4 Ohms 150W x 1 4 Ohms B config 80W x 5 2 Ohms 150W x 1 4 Ohms C config 80W x 5 2 Ohms 220W x 1 2 Ohms FILTERS INPUTS Subsonic Bypass 24dB Oct Hi Pass 16 32 Hz pre set at 20 H...

Page 13: ... a multichannel system These kits are available as accessories and consist of three elements 1 Volume adjuster VCRA VCRD 2 VCA VCA1D module to put inside the amplifiers 3 Wire to connect VCRA VCRD adjusters to the proper sockets in the amplifier rear panel and to the car lights switch in order to light it up Install VCRA VCRD adjusters in a place you can easily and comfortably reach according to t...

Page 14: ...ough It consists of two units to apply onto the amplifier sides each of them is provided with an electronically controlled fan Its intervention depends on a thermal sensor that starts the system as soon as LRx heat sink reaches 45 C The same sensor is connected to a special circuit which controls the two fans speed progressive increase when temperature increases too Air flux constant control allow...

Page 15: ...35 CONFIGURATIONS BLOCK DIAGRAM ...

Page 16: ...36 CONFIGURATIONS CONTROLS PANEL DIAGRAM AND SUBSONIC FILTER SWITCH FRONT REAR CENTER SUB CONFIGURATION EXAMPLE ...

Page 17: ... you seize both plate grips with your hands and pull them by blocking the silkscreen printed panel with your fingers against the amplifier chassis at the same time This will permit to remove the plate from the panel without damages 3 Remove the strip with audison logo 5 Mount the plate back by fixing it through the screws then re assemble the transparent cover which protects controls 4 Put the str...

Page 18: ...stalled about 10 cm far from the battery its value will have to be equal or slightly higher 10 approx than consumption 13 8 VDC according to the different configurations see Technical features It will have to be equal to the sum of the values of all fuses in case system consists of several amplifiers or in case amplifiers have several fuses AMPLIFIER FIXING COLLEGAMENTI ELETTRICI LRx 6 SR Direct F...

Page 19: ...39 INSTALLATION audison cable PRODUCTS FOR ELECTRIC CONNECTIONS ...

Page 20: ...tteria da 12V DC con un carico di 4 Ohm e tutti i canali in funzione Audison measurement standards Power measures taken according to audison standard 1998 edition 12VDC and 13 8VDC 1 kHz or crossover cut off frequency 0 3 THD nominal power 1 THD continuous power Tolerance 10 5 Continous power given by RMS Voltage measured on resistive load The nominal power of the amplifier is measured upon a batt...

Reviews: