background image

9

© 2002 Audiovox Electronics Corporation

128-6187

Summary of Contents for Exclusive EX-6000

Page 1: ... Vehicles With 12 Volt Negative Ground Electrical Systems Only Kit Contents 1 EX 6000 Control Module 2 Channel Code Learning Receiver 2 Three Button Transmitters 1 Multi Pin Input Output Harness 1 Two Pin Door Lock Harness 1 Two Pin LED Indicator 1 Two Pin Valet Programming Switch 1 Single Tone Siren 1 Installation Manual 1 Operator s Manual 1 Limited Warranty ...

Page 2: ...e compartment for maximum sound distribution Before securing the siren check behind your chosen location to assure that the mounting screws will not penetrate any factory wiring or fluid lines Secure the siren mounting bracket using 8 screws by first using the mounting bracket as a template scribe or mark the three bracket mounting holes Drill the three marked holes using a 1 8 drill bit than moun...

Page 3: ... harness These fuseholders each hold a separate ATC fuse one 5AMP and one 15AMP This RED wire must be connected to a constant power wire at the vehicle s ignition switch harness or fusebox Most vehicles have at least one battery source wire supplying power to the ignition switch Locate a constant power wire or power taping point either at the vehicle s ignition switch harness or fuseblock This wir...

Page 4: ...series type You may chose to use any of the diodes in this series with the 1N4003 and 1N4007 being the most common types The diodes must be installed with careful regard for their direction of current flow Note This wire will be shunted when remote control channel 2 is accessed trunk release This wire will remain shunted all the while there is ground present and for 5 seconds after the ground is r...

Page 5: ...ule Determine the door lock circuit of the vehicle you are working on and wire according to the diagrams shown WIRING FOR GROUND PULSE DOOR LOCK CIRCUITS This is a system commonly used on most import vehicle s factory door lock unlock systems and with a few domestic vehicles which employ factory keyless entry systems In this application the Red wire serves as the Lock output providing a ground pul...

Page 6: ...y wire is sequentially grounded under other conditions the unit will enter the various program modes Route the Black and Grey wires from the Valet Program Manual Override switch to the EX 6000 unit and plug the blue 2 PIN connector into the mating blue connector shell of the EX 6000 control module Do not force the connector it will only plug in one way Note Please refer to the section Programming ...

Page 7: ...important to note that when you first enter the Programming Mode you are automatically positioned to adjust the First Programmable Feature and that the Valet Program Manual Override Switch allows you to toggle from there through each of the four more programmable features However it will not allow you to return to any feature once you have toggled past it Should you accidentally toggle past the fe...

Page 8: ... to the next feature OR Toggle the Valet Program Manual Override Switch once to Advance to the next feature OR Turn the Ignition Switch OFFto exit the Programming Mode NOTE If you accidentallytoggled past the feature you intended to adjust you must exit and re enter the mode OR Toggle the Valet Program Manual Override Switch once to Advance to the next feature OR Toggle the Valet Program Manual Ov...

Page 9: ...9 2002 Audiovox Electronics Corporation 128 6187 ...

Reviews: