PROCEDURE FOR HORIZONTAL INSTALLATION
PROCEDURE FOR VERTICAL INSTALLATION
N O T E : If the anti-vibration spring position has been changed and verified for vertical
mounting (as shown on page 6), start with step 2.
Attach bracket (L) and bracket (R) to each side of the unit,using the hexagonal
bolts with washer base (M5 x 10).
Set the 4 anti-vibration springs to
position “v”
Determine the mounting location, and drill four mounting holes.
Secure the unit in place,using four self-tapping
screws(T5x12).
Use RTV(sillicone sealer)on screw threads or
around the holes to prevent moisture intrusion.
Never mount the unit near the fuel tank.
NOTE: Use seals (A) to cover unused
mounting holes on sides of unit.
Determine the mounting location,
and drill four mounting holes.
Mount the unit in place, using four
self-tapping screws (T5 x 12).
Use RTV(silicone sealer) on screw
threads or around the holes to
prevent moisture intrusion.
Attach bracket (L) and bracket (R) to
each side of the unit, using the
hexagonal bolts with washer base
(M5 x 10).
NOTE: Use seals(A) to cover
unused mounting holes on sides of
unit.
Anti-vibration
springs position
Bracket (L)
Bracket (L)
Bracket (R)
Bracket (R)
Bracket (L)
Bracket (R)
Hexagonal bolt
with washer base (M5 x 10)
Hexagonal bolt with
washer base (M5 x 10)
Drill holes 4mm in diameter.
Drill holes 4mm in diameter.
Bracket (L)
Bracket (R)
Self-tapping screw
(T5 x 12)
Self-tapping screw
(T5 x 12)
position “v”