background image

128-7402

1 of 28

Model APS-997

Installation Manual

SELECT

ABLE FEA

TURES

The selectable features can be set manually as explained below

, or with the RF feature programmer

.

T

o

 set features using the RF programmer

, follow the instructions packaged with the programmer

.

Factory default settings are indicated by bold text.

Note :

 The method of manual override can either be selected to operate from the valet switch or operate as custom code.

Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.

NOTE: Keyless Entry Models with no horn output will Flash the Parking Lights instead of chirp where chirp is indicated.

Also, No data will be indicated if a feature is not available for a particular model.  The unit will enter the feature but no s

election will be available.

RF Programmable Feature Bank 1 Is For T

ransmitter Programming See T

ransmitter Programming Guide.

RF Programmable Features Bank 2 Is Alarm Selectable Features:

Feature Selection

1 Chirp

2 Chirps

3 Chirps

4 Chirps

5 Chirps

6 Chirps

1st DoorL/UL

1 Sec.

3.5 

Sec.

1 Sec L, Dbl. U/L

Dbl L, 1 Sec UL

Dbl 

L, 

Dbl 

UL

l/350mS 

ul

2nd 

Accy 

Lock

Auto Lock On

Auto Lock Off

3rd Accy

UL

Auto UL Dr

.

Auto 

UL 

All

Auto UL Off

4th Headlights

On 

Arm

On 

Disarm

On Both

Off

5th Passive 

Locks

Passive

Active

6th Pass/Act Arm

Passive 

Arm

Active Arm

7th Siren/Horn

Siren/Horn

Siren Only

Horn 

Only

8th Horn Chirp

10mS

16mS

30mS

40mS

50mS

9th O/R Method

Custom 

Code

V

alet

10th 2 Step U/L

O

n

Off

1

1th Chp Del Tx

O

n

Off

12th V

olts/HdW

ire

Not A

vailable

13th Trigger Circuits

Not 

A

vailable

14th L/UL Poll

Not A

vailable

When using the RF programmer

, enter the program mode as follows:

Turn the ignition on

Press and release valet switch 3 times

turn ignition off then on

Press and hold valet switch for 5 seconds

Siren chirps 2 times indicating access to RF feature program mode.

Summary of Contents for 1287402

Page 1: ...able Feature Bank 1 Is For Transmitter Programming See Transmitter Programming Guide RF Programmable Features Bank 2 Is Alarm Selectable Features Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5...

Page 2: ...se the valet switch 2 chirps active locks Press transmitter Lock button to change 1 chirp passive locks or Sixth Press and release the valet switch 2 chirps active arming Press transmitter Lock button...

Page 3: ...0th Crank Time 0 8 Sec 1 0 Sec 1 5 Sec 2 0 Sec 11th Gas Diesel Gas Diesel 10 Diesel 15 Diesel 20 12th Transponder O P While R S On During Start Until Ign Off 13th Temp Start Off On 14th Crank Averagin...

Page 4: ...lease the valet switch 2 chirps crank time 1 0 sec Press transmitter Lock button to change 3 chirps crank time 1 5 sec Press transmitter Lock button to change 4 chirps crank time 2 0 sec Press transmi...

Page 5: ...pointed away from and out of the engine compartment for maximum sound distribution Before securing the siren check behind your chosen location to assure that the mounting screws will not penetrate any...

Page 6: ...isting factory wiring or fluid lines Drill a 9 32 hole in the desired location and mount the switch by passing it through the panel from the underside Secure the switch using the nut star washer Route...

Page 7: ...IONS TO THE VEHICLE HAVE BEEN MADE AF TER SELECTING YOUR TARGET WIRES AS DEFINED BELOW DISCONNECT THE NEGATIVE BAT TERY CABLE FROM THE VEHICLE BATTERY PRIOR TO MAKING ANY CONNECTIONS WIRING THE 6 PIN...

Page 8: ...art via RF control in any gear selection other than park or neutral In both mechanical and electrical neutral start switch configurations the connection of the Yellow wire will be made to the low curr...

Page 9: ...ngbrakeisappliedwheneverthevehicleissetupforandtheturbotimercircuitisused Thisinputmustswitchtogroundwhenthevehicle sparkingbrakeisapplied ConnecttheOrange Blackwire to the negative output of the vehi...

Page 10: ...ng Light Flasher Feed This wire is the common contact of the on board parking light flasher relay If the vehicle you are working on has 12 volt switched parking lights connect this wire to a fused 12...

Page 11: ...lighting see programming under title Completing The Installation Positive Door Switch Wiring Detail Dark Green Wire Instant Trigger Input This is the instant on ground trigger input wire This wire mu...

Page 12: ...tor within 5 of the key s value from the resistor pack supplied 2 Locate the pair of VATS wires in the vehicle usually a pair of thin gauge wires running from the ignition switch to the VATS control m...

Page 13: ...de must be used for ground switched brake light circuits and must be connected to the output of the brake switch Grey w Black Trace Negative Inhibit Safety Shut Down Detail Orange Wire Ground When Arm...

Page 14: ...e to operate the vehicle without the key while running under the control of the Remote Start In most vehicles in order to shift into gear the brake pedal must be depressed The brake input will in turn...

Page 15: ...o only one door switch no matter how many doors the vehicle has as most door lighting circuits are wired in parallel This wire will be shunted when remote starting the vehicle and will remain shunted...

Page 16: ...current output and should only be connected to the low current ground output from the vehicle s horn switch If the vehicle uses a 12 VDC horn switch then connect the black w white trace wire to termin...

Page 17: ...he starter output until this wire drops the 12 volts In other words in a Diesel vehicle with glow plug preheat circuit when the ignition is turned on the vehicle will not crank until the glow plugs ar...

Page 18: ...The Black Grey twin lead wires loaded in the two pin blue connector are the ground supply and program valet override input of the Remote Start unit When the Grey wire is grounded under certain conditi...

Page 19: ...door unlock motor wire and cut it at a convenient location to allow wiring of an optional relay Connect the door side of the cut wire to terminal 30 of the optional relay added Connect the vehicle sid...

Page 20: ...30 of the optional relay added Connect the vehicle side of the cut wire to terminal 87a of the optional relay added Connect the red wire of the 3 pin harness to terminal 86 of the optional relay adde...

Page 21: ...o select 2 or 4 hour automatic start timer 1 Start with the Enable switch Red Handle in the On Position 2 Turn the ignition on then off 3 Within 10 seconds of the key turning off cycle the enable swit...

Page 22: ...ress and hold the valet program push button switch then start the vehicle using the key 5 When the unit senses the tach signal the parking lights will begin to flash 6 Release the valet program pushbu...

Page 23: ...rty damage or both HOOD PIN SAFETY SHUT DOWN The intention of the hood pin safety shut down is to prevent the Remote Start unit from being activated while a mechanic or vehicle owner is performing nor...

Page 24: ...he Remote Starts Wiring to accommodate this vehicle The information concerning the Mechanical Neutral Safety Switch provided below will help you to determine if the vehicle you are working on has this...

Page 25: ...e the vehicle is running under the control of the Remote Start the vehicle will shut down This must be explained to the operator as it is in contrast to the normal opera tion of a vehicle utilizing an...

Page 26: ...ground C Locate the key in sensor switch wire that connects the chime module to the ignition cylinder D Cut this wire and connect the ignition cylinder side to terminal 30 of a P B VF45F11 or equival...

Page 27: ...y start with all doors closed 1 Use the transmitter to Lock Unlock Lock Unlock Lock Unlock Lock the system The LED turns on solid to confirm the system entered the learn mode 2 Immediately open and cl...

Page 28: ...128 7402 28 of 28 28 2005 Audiovox Electronics Corp Hauppauge NY 11788 999 audiovox com For Custom er Service Visit O ur W ebsite At Product Inform ation Photos FAQ s O wner s M anuals 128 7402...

Reviews: