each code, then the system will begin arming.  If the LED flash pattern reports the
previously stored code, the new code was not entered correctly.  Please repeat
steps 1 through 7 above considering the following.
NOTE: Acceptable digits 10ths or units are 1 through 9.  The unit will not recognize

a 0 (Zero), or no digit entered in any place, units or tenths.

NOTE: If 15 seconds of inactivity expire, or if the ignition switch is turned off for

more then 5 seconds during any of the above steps, the unit will revert
back to the last successfully stored code.

Custom Code Programming Example:
To Change the code from the factory pre-assigned code of 11 to “52” you would do
the following:

1. Disarm the system by use of the transmitter, or by use of the emergency

override sequence.

2. Turn the ignition switch to the on position.
3. Within 10 seconds, press and release the valet/override switch, 3 times.
4. Within 10 seconds turn the ignition switch off, on, off, on, off, on.

(The siren or horn will beep and the lights will flash one time.)

5. Within 10 seconds, begin to press and release the push button switch to set

the tenths digit.
(As per the example, press and release 5 times to set the tenths digit to 5)

6. Within 10 seconds of the last press of the push-button, turn the ignition switch

off then on.

7. Within 10 seconds, begin to press and release the push button switch to set

the units digit.
(As per the example, press and release 2 times to set the units digit to 2).

8. Turn the ignition switch to the off position.  Immediately observe the LED flash

pattern.

You will note the LED flashing five times, pause, and then flash two times, pause.
This pattern will be repeated three times indicating the new code (52) has been
accepted and stored in memory.
NOTE: If after step 8, the LED flashes a code other than what was just entered,

this indicates that the code has not been changed.  You will have to repeat
steps 1 through 7 above being certain to note the following:

Acceptable digits 10ths or units are 1 through 9.  The unit will not recognize a 0
(Zero), or no digit entered in any place, units or tenths.
NOTE: If 15 seconds of inactivity expire, or if the ignition switch is turned off for

more then 5 seconds during any of the above steps, the unit will revert back
to the last successfully stored code.

MANUALLY OVERRIDING YOUR SYSTEM:
USING THE CUSTOM CODE OVERRIDE
Assuming the override code programmed has not been changed, and the default
override code of 11 is in the system's memory.

Summary of Contents for 1285755

Page 1: ...de Grabbing Technology w Selectable Manual Override Mode w Remote Panic in all modes w Protected Valet w User Programmable Manual Override Code w 7 Function LED Light Emitting Diode Arm Disarm Zone 1...

Page 2: ...sing a siren the vehicle horn or both for the sounding device Where the siren is referenced below the horn or both may in fact chirp or beep ARMING THE SYSTEM ACTIVE 1 Turn off the engine exit the veh...

Page 3: ...ve arming PROTECTION WHILE THE SYSTEM IS ARMED Opening any protected door hood or trunk lid will cause the alarm to immediately sound The alarm will continue to sound for 30 seconds then stop and cont...

Page 4: ...f the optional 2 step door unlock circuit is installed when the unlock transmitter button is activated the drivers door only will unlock press ing the unlock button a second time will cause all doors...

Page 5: ...rve the red dash mounted LED to identify which zone was triggered If the LED is flashing one time pause one time pause etc then an intrusion attempt was made to the shock sensor or an accessory trigge...

Page 6: ...ide Code Unlike override switches easily found and defeated this security system allows the consumer to program a personal override code offering a higher level of security To take advantage of this o...

Page 7: ...example press and release 5 times to set the tenths digit to 5 6 Within 10 seconds of the last press of the push button turn the ignition switch off then on 7 Within 10 seconds begin to press and rele...

Page 8: ...henever the chirps are by passed the 4 chirp intrusion indicator and 3 chirp defective zone indicator will always operate Since these are important warnings to you that something has happened they can...

Page 9: ...ansmitter for up to 8 seconds for continuous output or press and release for momentary activation The optional accessory will immediately engage Check with your installation center for more informatio...

Page 10: ...ED 4CHIRPS DISARM INTRUSION These chirps are optional and can be de activated PARKING LAMP INDICATORS 1 FLASH ARM 2 FLASHES DISARM 3 FLASHES DISARM INTRUSION Your System Has These Features Activated o...

Reviews: