TROUBLESHOOTING
Conditioner will not power up
If the front operation indicator LED is NOT illuminated, follow the procedure outlined below. If
one step succeeds in activating the power, STOP there and ignore the other steps.
1.
Turn the hydraulic breaker off.
2.
Check at the back of the power conditioner to make sure the 32-amp Neutrik powerCON
connector is pushed all the way into the jack on the back of the power conditioner.
3.
Make sure the AC cord is plugged into the wall outlet.
4.
Check your household electrical box to make sure the circuit breaker has not been
tripped. If it has, flip the breaker back on.
5.
If the breaker trips again, check the entire length of the power cable to ensure there has
been no damage to it. If breaker doesn’t trip, jump to step 9.
6.
If no damages are visible on cable, disconnect the power conditioner from the wall outlet.
7.
Flip the house hold electric box breaker again.
8.
If the breaker trips again, call to electric specialist to check your house electrical
installation.
9.
If the breaker doesn’t trip in step 5, put the power conditioner hydraulic breaker in the
ON position.
10.
If all of these steps fail to return power to the power conditioner, consult Audiotricity or
authorized dealer for service.
Power conditioner hydraulic breaker trips every time I turn the unit on
Don’t try to power on the power conditioner again and contact Audiotricity or an authorized
dealer for service.