background image

 

To  activate  the  monitor  input  please  push  the 

monitor/set

  button  for  a 

short time. The originally selected input remains active for recording. 

 

This input can be chanced during the monitor loop is activated, of course. 
To  come back to the standard input simply press the described button a 
second time. 

 

 

Your  PRE  1  G2  is  programmable  for functions providing you with new 
and  easy  possibilities  to  adjust  the  system  to  your  needs.  All  individual 
settings will be remembered, also when PRE 1 G2 will be switched off the 
mains or transported. 

 

You can program the following: 

 

¨ 

The balance can be adjusted to individual preferences 

 

¨ 

Inputs, which usually have different signal level, can be adjusted to the 
same volume 

 

¨ 

Inputs can be given an individual name. 

 

¨ 

The brightness of the display can be adjusted ("Dim Value") 

 

¨ 

Automatic startup can be switched on or off ("Autostart") 

 

¨ 

You can choose between two texts being displayed while in stand-by 
mode ("Off_Text") 

 

 

The  2-line  alphanumeric  display  will  give  you  all  information  you  need 
about your individual settings: 

 

§ 

Number  of  selected  input  and  given  name  of input or number of se-
lected input and monitor or assigned name 

§ 

Volume and assigned offset, visualized balance setting as well 

 

Monitor loop 

Programming 

Display 

Summary of Contents for PRE I G2

Page 1: ...Audionet PRE I G2 Stereo Pre Amplifier Owner s Manual ...

Page 2: ...system is designed for absolute natural music reproduction and for highest user comfort The following will give you all information about how to operate your PRE 1 G2 Please read this carefully before the first use Following these instructions your PRE 1 G2 will give you long lasting pleasure and satis faction ...

Page 3: ... With the PRE 1 G2 comes a yellow green ground cord for optimal ground connection Please connect this additional ground cord to the plug 10 at the back of the PRE 1 G2 and put the plug into a socket near to the power cord The Audionet PRE 1 G2 is a very sensitive system Please ensure that all used connector cables are in absolutely best condition For connecting or removing audio sources PRE 1 G2 h...

Page 4: ... the pre amplifier and the recorder Therefore every signal source that should be recorded has to be connected to the remaining inputs Your PRE 1 G2 is fitted with a monitor loop This enables you to listen to the recorder without interrupting the signal source being recorded To use this feature please connect the inputs and outputs of the recorder with the corresponding monitor output and input 7 o...

Page 5: ... stand by state displaying Audio net Switching off the mains at the rear is only necessary in cases of longer absence like holidays In this case please press again the mains power switch on the rear Looking from above the switch now shows you a 0 and the display turns off NOTE All systems connected with the outputs must be off and powered down when PRE 1 G2 is to be switched on or off the mains at...

Page 6: ...lockwise if higher and counterclockwise if lower volume is desired The PRE 1 G2 shows you the master volume with a range of 86 dB This corresponds to 80 dB to 6 dB At 0 dB the amplitudes of input and output signal are equal To adjust the volume offset for each separate channel please read programming below The volume knob is an incremental impulse unit without a stop Please turn the input button a...

Page 7: ... or transported You can program the following The balance can be adjusted to individual preferences Inputs which usually have different signal level can be adjusted to the same volume Inputs can be given an individual name The brightness of the display can be adjusted Dim Value Automatic startup can be switched on or off Autostart You can choose between two texts being displayed while in stand by ...

Page 8: ... number and offset adjust 3 Turn the volume knob to adjust the desired channel level This is pos sible within a range of 9 1 dB to the master volume 4 To leave the programming mode push the monitor set a short time Alternatively you can proceed adjusting to the next step with another long keypress go on with 3 in this case 1 Select the channel to be given a new name 2 Push the set button twice for...

Page 9: ...ins switch 3 until the power button is pushed If autostart is set to ON the PRE 1 G2 starts automatically into the on mode after switching on with the mains switch 3 Select this option if you use a timer to control the PRE 1 G2 2 Select the autostart option by turning the volume knob 3 To leave the programming mode push the monitor set a short time Alternatively you can proceed adjusting to the ne...

Page 10: ...ollowing functions are possible PRE 1 G2 has a soft mute function If desired to mute PRE 1 G2 please press the mute button on the remote control When muting PRE 1 G2 regulates volume down to 80 dB and then switches off the outputs If you press the mute button again PRE 1 G2 activates the outputs and re turns to the volume before If the mains phase is connected incorrect the PRE1 G2 will tell you w...

Page 11: ...IDEKTRON mains This unit must be earthed AC 230 240 V 50 60 Hz output monitor rec out in 2 6 5 tape 3 2 4 5 6 7 phono out out ext power Use dedicated only 1 gnd Idektron GmbH Co KG Bochum Germany PRE I 0 I Rear View Audionet PRE I G2 3 2 1 4 9 5 7 6 8 ...

Page 12: ... are optimized using the most modern discrete circuitry The volume is regulated by a precision resistor network instead of a simple and fault susceptible potentiometer The PRE 1 G2 is driven by a microcontroller system Information about the current state is shown by a 2 16 character display Input names can be set individually as well as the volume offset of each input channel There is a separate m...

Page 13: ... 1 RCA monitor input gold plated 7 pin plug for Audionet EPS Outputs 1 line out RCA output gold plated 1 balanced XLR output gold plated 1 GND 2 Pos 3 Neg 1 rec out RCA output gold plated 1 RCA monitor output gold plated 1 plug for additional ground connection gold plated 1 Audionet Link optical Mains power consumption 230 V 50 Hz 7 VA Stand by max 30 VA dimensions weight 430 mm 70 mm 310 mm w h d...

Page 14: ...ure or any liquid to get into the unit Set up the unit in a free position so that the air is al lowed to flow through the unit slits Do not cover e g with a blanket Do not open the case Unauthorized opening will cause loss of guarantee Use a dry cloth for cleaning Engineered and produced by Idektron GmbH Co KG Herner Str 299 Gebä ude 6 44809 Bochum www audionet de contact audionet de ...

Reviews: