background image

AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR 

WARNING: SHOCK HAZARD-DO NOT OPEN

the third prong is provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched 
particularly at the plugs, convenience receptacles, and at 
the point where they exit from the apparatus.

Use only with the cart, stand, tripod, bracket, 
or table specified by the manufacturer, or 
sold with the apparatus. When a cart or rack 
is used, use caution when moving the cart/
apparatus combination to avoid injury from 
tip-over.

Unplug the apparatus during lightning storms or when 
unused for long periods of time.

Refer all servicing to qualified service personnel. Servicing 
is required when the apparatus has been damaged in any 
way, such as power supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

CAUTION:

 These servicing instructions are for use by 

qualified service personnel only. To reduce the risk of 
electric shock, do not perform any servicing other than 
that contained in the operating instructions unless you are 
qualified to do so.

Do not install this equipment in a confined or built-in space 
such as a bookcase or similar unit, and keep well ventilated 
in open space. The ventilation should not be impeded 
by covering the ventilation openings with items such as 
newspaper, table-cloths, curtains etc.

WARNING: 

Excessive sound pressure from earphones and 

headphones can cause hearing loss. 

WARNING: 

Only use attachments/accessories specified or 

provided by the manufacturer (such as the exclusive supply 
adapter, battery etc).

CAUTION: 

Danger of explosion if battery is incorrectly 

replaced. Replace only with the same or equivalent type. 

WARNING: 

The battery shall not be exposed to excessive 

heat such as sunshine, fire or the like. 

WARNING: 

Please refer to the information on the exterior 

panel of the enclosure for electrical and safety information 
before installing or operating the apparatus.

WARNING: 

For the terminals marked with symbol of “

   

” 

may be of sufficient magnitude to constitute a risk of electric 
shock. The external wiring connected to the terminals 
requires installation by an instructed person or the used of 
ready-made leads or cords.

Mains Supply: 

The mains operating voltage of M-ONE is 

shown on the rear panel. If this voltage does not match the 
mains voltage in your area, consult your Audiolab dealer 
about converting the unit.

The mains supply fuse on the rear panel is accessible when 
the IEC mains plug has been removed. In the rare event 
that it has broken, check for any obvious cause before 
replacing the fuse with one of the correct rating and type. 
The fuse values are:

220 - 240V (UK, Korea, etc.) T2AL 250V 20mm Slow Blow

100 - 120V (USA, Japan, etc.) T4AL 250V 20mm Slow Blow

This equipment is a Class II or double insulated 
electrical appliance. It has been designed in 
such a way that it does not require a safety 
connection to electrical earth.

2; !Jnqpsubou!Tbgfuz!Jogpsnbujpo!!

Page 1

IMPORTANT SAFETY INFORMATION

Read these instructions.

Keep these instructions.

Heed all warnings.

Follow all instructions.

Do not use this apparatus near water.

Clean only with dry cloth.

Do not block any ventilation openings. Install in 
accordance with the manufacture’s instructions.

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding plug has two 
blades and a third grounding prong. The wide blade or 

This lightning flash with arrowhead symbol within an 
equilateral triangle is intended to alert the user to the 
presence of non-insulated “dangerous voltage” within the 
product’s enclosure that may be of sufficient magnitude 
to constitute a risk of electric shock. Warning: to reduce 
the risk of electric shock, do not remove the cover (or 
back) as there are no user-serviceable parts inside. Refer 
servicing to qualified personnel. The exclamation point 
within an equilateral triangle is intended to alert the user 
to the presence of important operating and maintenance 
instructions in the literature accompanying the appliance.

$+021(LQGG

Summary of Contents for M-ONE

Page 1: ...Vtfs Jotusvdujpot N POF 0 21 LQGG ...

Page 2: ...l of the enclosure for electrical and safety information before installing or operating the apparatus WARNING For the terminals marked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the used of ready made leads or cords Mains Supply The mains operating voltage of M ...

Page 3: ... for iPhone iPad iPod Signal Output Loudspeaker output Operating Features Bluetooth aptX wireless high fidelity Lossless transmission Automatic detection decoding of external digital input source Selectable digital fillers setting 3 Hfuujoh Tubsufe Page 2 Mute and balance remote controls Automatic trigger post equipments via 12V trigger output Three display brightness available with on off options...

Page 4: ...4 Dpouspmt boe Dpoofdupst Page 3 0 21 LQGG ...

Page 5: ... replay the current track of CD USB Press again to move to the previous track of CD USB 11 STANDBY Press to bring the unit in out of Standby Battery Caution There is a risk of fire and burns if the battery is handled improperly Do not disassemble crush puncture short external contacts or dispose in fire or water Do not attempt to open or service the battery Replace only with a CR2025 battery Disca...

Page 6: ...ia player to stereo 6 Dpoofdujpot Page 5 SPDIF Inputs one coaxial and one optical inputs are provided for connect the M ONE to an external SPDIF source Connect a suitable video or optical cable from the SPDIF output of the source component to the appropriate input of the M ONE 12V Trigger Input If you have a Audiolab system we advise connecting the triggers This will enable all Audiolab units to b...

Page 7: ...the DISPLAY button on the remote control to cycle through the display levels When the display is set to OFF Pressing any key will bring the display on After a few moments the display will again switch off Footnotes on the Display The M ONE provides a true reading of the digital input frequency For example when a stable 44 1kHz input is present you may see the display vary between 44 100k and 44 10...

Page 8: ...filters and 4 DSD filters available Press the remote control MENU key to enter menu mode press or to access the Digital Filter or DSD Bandwidth menu page press to enter the filter page press or again to select a different filters press again to confirm the chosen filter Pressing the SEL knob on the front panel can also enter the menu mode rotating this knob turns the menu page to Digital Filter or...

Page 9: ...ault settings are at the top DSD Bandwidth Normal DSD Bandwidth 50k DSD Bandwidth 60k DSD Bandwidth 70k Track Time Show If Available Track Time Do Not Show Sampling Rate Nominal Frequency Sampling Rate Actual Frequency Jitter Rejection Automatic Jitter Rejection Low Bandwidth Jitter Rejection Medium Bandwidth Jitter Rejection High Bandwidth Default Input Recall Last Input Default Input COAX Defaul...

Page 10: ...carried out by parties other than Audiolab or its authorized agents or distributors 2 Products not purchased from an Audiolab authorized dealer 3 Products that were not new at the time of original purchase 4 Products sold as is as seen or with all faults Repairs or replacements as provided under this warranty are the exclusive remedy of the consumer Audiolab shall not be liable for any incidental ...

Page 11: ...utput 2 x 36W RMS 8 ohm Frequency response 3dB 10Hz 30kHz Ref 1kHz 1dB 20Hz 20kHz Ref 1kHz Total harmonic distortion THD 0 01 1kHz 1W 20Hz 20kHz Signal to noise ratio S N 81 1W 1kHz Standby Power Consumption 0 5W Dimensions W x H x D 246 5 x 114 x 295 mm Carton size W x H x D 411 x 227 x 415 mm Net weight 5 5kg Gross weight 6 5kg Power Requirements depending on region 220 240V 50 60Hz 100 120V 50 ...

Page 12: ...e PE29 7DL UK Tel 44 0 1480 452561 Fax 44 0 1480 413403 http www audiolab co uk IAG reserves the right to alter the design and sepcifications without notice All rights reserved IAG Group Ltd Audiolab is a member of the International Audio Group 0 21 LQGG ...

Reviews: