2. SAFETY RELATED SYMBOLS

This symbol, wherever used, alerts you 

to the presence of un-insulated and 

dangerous voltages within the product 

enclosure. These are voltages that may be suf

-

fiecient to constitute the risk of electric shock or 

death.

This symbol, wherever used, alerts you to impor

-

tant operating and maintenance instructions.

Please read.

     

Protective Ground Terminal.

AC mains (Alternating Current)

AC mains (Alternating Current)

ON:

 Denotes the product is turned on.

OFF:

 Denotes the product is turned off.

Warning

Describes precautions that should be observed 
to prevent the possibility of death or injury to the 
user.

Caution

Describes porecautions that shuld be observed to 
prevent damage to the product.
Disposing of this product should not be placed in 
municipal waste but rather in a separate collection.

Warning

Power supply

Ensure that the mains source voltage (AC outlet) 
matches the voltage rating of the product. Fail

-

ure to do so could result in damage to the prod

-

uct and possibly the user. Unplug the product 
before electrical storms occur and when unused 
for long periods of time to reduce the risk of 

electric shock or fire.

External Connection

Always use proper ready-made insulated mains 

cabling (power cord). Failure to do so could 

result in shock/death or fire. If in doubt, seek 

advice from a registered electrician.

Do Not Remove Any Covers

Within the product are areas where high volt

-

ages may present. To reduce the risk of electric 
shock do not remove any covers unless the AC 
mains power cord is removed. Covers should be 

removed by qualified service personnel only.

No user serviciable parts inside.

Fuse

To prevent fire and damage to the product, use 

only the recommended fuse type as indicated in 

this manual. Do not short-circuit the fuse holder. 
Before replacing the fuse, make sure that the 
product is off and disconnected from the AC 

outlet.

Protective Ground

Before turning the unit ON, make sure that it is 

connected to ground. This is to prevent the risk 
of electric shock.
Never cut internal or external Ground wires. 
Likewise, never remove Ground wiring from the 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN.

CAUTION!

Summary of Contents for LIVE AN SPLIT

Page 1: ...P 1 AUDIOLAB Live AN Split LIVE AN SPLIT Professional splitter mixer USER MANUAL...

Page 2: ...dance 50 kOhms balanced 25 kOhms unbalanced Nominal operating level 10 dBV to 4 dBu Max input level 21 dBu balanced and unbal anced CMRR Typ 40 dB 55 dB 1 kHz Audio Outputs Connectors XLR and 1 4 TRS...

Page 3: ...ld result in damage to the prod uct and possibly the user Unplug the product before electrical storms occur and when unused for long periods of time to reduce the risk of electric shock or fire Extern...

Page 4: ...e designed for your safety Do not remove Ground connections If the plug does not fit your AC outlet seek advice from a qualified electrician Protect the power cord and plug from any physical stress to...

Page 5: ...d output while for each individual channel mono ap plication is configured So if the stereo main signal is split into the mono channel output Front panel 1 MAIN INPUT LEVEL control This knob is used t...

Page 6: ...nue use of this unit before repaired 12 AC inlet This connector is meant for the connection of the supplied main cord Do not insert power cable into the unit until the volt age has been correctly set...

Page 7: ...dded In this application use the SPLIT MIX switcht o select the SPLITTER operational mode for each mono channel apply the main signal from the MAIN IN sockets and get the 6 outputs from the mono OUTPU...

Page 8: ...P 8 AUDIOLAB Live AN Split English version Stereo Keyboard Guitar Computer Desktop Paging Microphone Wireless Tie Clip Wireless Handheld MIC DVD Player...

Page 9: ...AN Split is made by using the enclosed mains cord and a standard IEC receptable It meets all of the inter national safety certification requirements Audio Connection The Live AN Split presents with b...

Page 10: ...d Unbalanced Rack Mounting The most secure mounting is on a universal rack shelf available from various rack manufactures or your music dealer The Live AN Split fits into one standard 19 rack unit of...

Page 11: ...LAB Live AN Split English version 6 BLOCK DIAGRAM Note The supplier will not assume responsibility for errors or omissions in the manual The information in this manual is subject to change without pri...

Page 12: ...RF Impedancia 50 kOhms balanceada 25 kOhms desbalanceada Nivel de operaci n nominal 10 dBV a 4 dBu Nivel m ximo de entrada 21 dBu balanceado y desbalanceado CMRR 40 dB 55 dB 1 kHz Salidas de audio Con...

Page 13: ...ga el ctrica riesgo de muerte o incendio Desconecte el equipo durante tormentas el c tricas o si no lo va a utilizar durante periodos largos de tiempo Conexi n externa Utilice un cable de suministro e...

Page 14: ...mine la conexi n a tierra Si el enchufe suministrado no encaja en la toma p ngase en contacto con un electricista para sus tituir la toma antigua Para reducir el riesgo de descarga el ctrica prote ja...

Page 15: ...al est reo principal se divide en la salida del canal mono o la se al de entrada mono se env a al bus de salida Panel frontal 1 Control MAIN INPUT LEVEL Utilice la perilla para regular el nivel de la...

Page 16: ...proceda con su reparaci n 12 Entrada de CA Utilice este conector para el cable de alimentaci n principal No conecte el cable en la unidad hasta que el voltaje se haya configurado correctamente No cone...

Page 17: ...ilice el interruptor SPLIT MIX para seleccionar el modo splitter para cada canal mono Aplique la se al principal de los conectores MAIN IN y obtenga las seis salidas de los conectores de salida mono d...

Page 18: ...P 18 AUDIOLAB Live AN Split Versi n Espa ol Teclado est reo Guitarra Computadora Micr fono de escritorio Clip sujetador inal mbrico Micr fono de mano inal mbrico Reproductor DVD...

Page 19: ...n el ctrica del LIVE AN SPLIT se lleva a cabo utilizando el cable de alimentaci n incluido y un recept culo IEC est ndar Cumple con todos los requisitos internacionales de certificaci n de seguridad...

Page 20: ...n estanter a Para garantizar un montaje seguro procure uti lizar una estanter a o rack universal P ngase en contacto con su proveedor o un distribuidor de m sica para conseguirla LIVE AN SPLIT cabe en...

Page 21: ...QUES Main izquierda Main izquierda Main derecha Main derecha Enlace Nivel Nivel Nivel Nivel Nivel Nivel Observaci n El proveedor no asumir responsabilidad por los errores u omisiones del manual La inf...

Page 22: ...P 22 AUDIOLAB Live AN Split audiolab amproweb com...

Reviews: