Speaker systems must only be operated by trained persons.

Danger of Life due to crashing speaker systems or hearing loss due to excessive sound pressure levels! The different local conditions have to be 

considered in terms of safety rules.

When using smoke machines, make sure that the speaker system is never exposed to the direct smoke jet and is installed in a distance of 0.5 meters 

between smoke machine and speaker system. 

The ambient temperature must always be b3° C and +45° C. Keep away from direct insulation(particularly in cars) and heaters.
This speaker system must only be installed at a solid, plane, anti-slip, vibration-free, oscillation-free and fire-resistant location.

 

     LEGAL INSTRUCTIONS:

Operating an amplification system can produce extremely high noise levels that may cause a permanent hearing loss. The legal ins

-

tructions for using an amplification system vary from country to country. The user must always inform himself on the legal instructions 
valid in his country and apply them to his situation.  Always monitor the sound pressure level when operating an amplification system in 
discotheques, concerts etc. Never exceed the permissible noise level exposures as specified by your authorities. The monitoring of the 

noise levels must be documented in an appropriate way.

Hearing damage caused by high noise levels can be treated as physical injury and persecuted by law. Please note that the organizer is 
responsible for keeping to a specified noise level. If this noise level will be exceeded, the event may be cancelled immediately.
If the organizer does not fulfill his safety duties, he is reliable by civil law for any damages occurred, e.g.: Pay the treatment costs of the 

damaged person, pay a smart money to the damaged person.

Economic damage caused can be demanded from the operator of the amplification system. If hired persons work with amplification sys

-

tems: the noise levels of music events are almost always too high. This is why the entrepreneur has to set up warning signs and provide 

hearing protectors. The staff has to use these.

AudioFocus© cannot be made liable for damages caused by incorrect installations and excessive noise levels.

Please note: 

When using this speaker system in public or industrial areas, a series of safety instructions have to be followed that this manual can only give in part. 
The operator must therefore inform himself on the current safety instructions and consider them.

Before installing the system, make sure that the installation area can hold a minimum point load of 8 times the system’s load (e.g. weight 20 kg - point 

load 160 kg).
The speaker system must never be installed higher than 100 cm without secondary attachment.

For overhead use (mounting height >100 cm), always fix the speaker system with an appropriate safety rope.

DANGER!

This speaker system must only be suspended by experienced and trained persons - Danger to Life due to crashing speaker systems!

If the original speaker system is equipped with an appropriate flange, this speaker system can be installed on top of a subwoofer (satellite system), on a 

speaker stand, an appropriate stand or an appropriate wall-mounting. The carrying capacity of the distance-tube, the speaker

stand, the stand or the wall-mounting must never be exceeded. 

The Top units must always provide enough stability. The Sub unit base surface must always be sufficiently dimensioned in relation to the top speaker in 

order to prevent tilting over.

Operate the speaker system only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the speaker 

system. Most damages are the result of unprofessional operation!

Speaker systems must never be transported with cranes. Never stack heavy objects on this speaker system. Persons must never climb onto this spea

-

ker system. 
Never use solvents or aggressive detergents in order to clean the speaker system! Rather use a soft and damp cloth.

Please consider that unauthorized modifications on the speaker system are forbidden due to safety reasons!

If this speaker system will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee 
becomes void. Furthermore, any other operation may lead to dangers like crashes, hearing loss etc.

!

!

Summary of Contents for FR-X SYSTEM

Page 1: ...FR X user s manual www audiofocus eu FR X SYSTEM USER MANUAL ...

Page 2: ...Hz model dependant the rotatable AF horn generates a 80 x30 asymmetric directivity pattern The FR X rigging system allows assembling a horizontal or vertical array with constant curvature Coupling between traditional horns causes a lot of comb effects resulting in poor sound projection and coherence in the space due to bad coupling between cabinets Thanks to the AF horn and specific DSP treatment ...

Page 3: ...erfect coupling a Put the cabinets side by side and line up the cargo points b Sliding of the H profile to make the coupling The AUDIOFOCUS H profile fits the cabinet cargo hardware perfectly to join cabinets c Slide the two H profiles in the top and bottom cargo profiles ...

Page 4: ...ce the H profiles are fully inserted 1 connect the front and rear M10 shackles to lift the complete set 2 Examples of configurations FR X vertical coupling 2 x FR X on truss cargo FR X horizontal coupling FR X pole mounted 1 2 ...

Page 5: ...ble 80 x30 horn in FR X cabinets can be adjusted without any tools Remote the front grill magnet Access to the 80x30 horn is easy Remove the 4 hand nuts Rotate the horn to the position required and tighten the 4 hand nuts H30 x V80 H80 x V30 80 30 80 30 ...

Page 6: ... fuse with the same type and value T10A 240V 3 Make sure that the power switch is set to OFF before you connect the devices 4 A good cable improves the sound quality Input cables should be as short as possible 5 If long cable are necessary you should use balanced cables Dagnosis and status Leds Limit ON when output signal is 3dBspl of the peak Temp ON when working temperature is too high The inter...

Page 7: ...ection V X Comb philosophy and setup Basical explanation about X comb technology Coupling between two sources that are discontinued makes appear a comb effect problem This mean that if you walk in front of the cabinets that are coupled you will feel some holes and maximum due to the distance the sources and the ears Some frequencies arrives in phase and other ones out of phase The earing system fe...

Page 8: ...trated below Note that left and right stacks are mirrored d With four FR X per side your cabinet positions will be as follows e Set your presets Odd ranks 1 3 5 have to be placed in preset 3 Even ranks 2 4 6 have to be placed in preset 4 Preset 4 Preset 3 Preset 4 Preset 3 Preset 3 Preset 4 Preset 3 Preset 4 Left stack Right stack 4 3 2 1 1 2 3 4 ...

Page 9: ...the surface must be treated with an appropriate fire retardant in regular intervals DANGER TO LIFE A crashing speaker system can cause deadly accidents All safety instructions given in this manual must be observed Before the speaker system is switched on all faders and volume controls have to be set to or min position HEALTH HAZARD By operating speaker systems with an amplifier you can produce exc...

Page 10: ...ring protectors The staff has to use these AudioFocus cannot be made liable for damages caused by incorrect installations and excessive noise levels Please note When using this speaker system in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consi...

Page 11: ...FR X user s manual 11 ...

Page 12: ...FR X user s manual Rue Fontaine St Pierre 1A 5330 Assesse Belgium Tel 32 83 21 80 54 Email sales audiofocus eu Web www audiofocus eu ...

Reviews: