AudioCodes  MP-124  FXS Patch Panel: Mount the Patch Panel in a 19-inch rack. Insert and fasten the 

Patch Panel's 50-pin male connector to the MP-124 50-pin female Telco connector. Connect your 

analog equipment to the Patch Panel using RJ-11 cables. 

3.

 

Connect two 18-AWG wires to the DC terminal block (ensure correct polarity), and then secure the DC 

terminal block to the MP-124 DC inlet. Connect the other end of the DC cable to a -48 VDC power 

supply; The Ready LED first flashes amber and then turns green after initialization completes. The Lan 

LED turns green indicating an Ethernet link. 

4.

 

For desktop mounting, simply place MP-124 on a horizontal desk. For 19-inch rack mounting, refer to 

the 

Hardware

 

Installation Manual

5

 

Assigning an IP Address 

Your MP-124 is shipped with a default IP address: 

 

IP Address:10.1.10.10 

 

Subnet: 255.255.0.0   

 

Default Gateway: 0.0.0.0 

 

To change the IP address: 

1.

 

Unplug MP-124 from the network and reconnect the Ethernet port directly to a PC’s LAN port, using 

an Ethernet crossover cable. 

2.

 

Change your PC’s IP address and subnet mask to correspond with the MP-124 default IP address and 

subnet mask (see above). 

3.

 

In your Web browser, enter the default IP address of MP-124 (e.g., http://10.1.10.10); the MP-124 

Web-based management tool opens, requesting your login credentials. 

4.

 

Log in using the default (case-sensitive) username ("Admin") and password ("Admin"), and then click 

Login

5.

 

Access the Interface table (Configuration tab > VoIP menu > Network > IP Interfaces Table). 

6.

 

Modify the IP address to correspond with your network IP addressing scheme, and then click Submit.  

7.

 

Save your settings to flash ("burn") in the Maintenance Actions page (Maintenance tab > 

Maintenance  menu > Maintenance Actions);  your Web browser disconnects from the MP-124 Web 

interface. 

8.

 

Unplug MP-124 from your PC and reconnect it to the network.  

9.

 

Restore your PC’s IP address and subnet mask to their original settings, and then restart your PC and 

re-access the MP-124 Web interface with its newly assigned IP address. 

6

 

Configuring Basic SIP Settings 

Configure MP-124 with basic SIP parameters using the Web interface: 

 

To configure basic SIP parameters: 

1.

 

In the Coders Table page (Configuration tab > VoIP menu > Coders and Profiles > Coders), configure 

coders used by MP-124 that best suit your VoIP network and are supported by your VoIP provider. 