P a g e

 

 

 

Cabling the Device for Power 

Depending on ordered model, your device can be powered either from a standard alternating current (AC) 

electrical wall outlet or a -48V DC power source. 

 

Warning:  

 

The device must 

always

 be grounded.  

 

If the FXS wires exit the building, they must be 

surge protected

 using gas discharge arrestors. For more 

information, refer to the device's 

Hardware

 

Installation Manual

.

 

 

1.

 

GROUNDING:

 Connect a grounding lug that is attached to your grounding wire to the device, using the 

terminal screw located on the rear panel. Attach the grounding wire to the equipotential grounding 

busbar. For more information, refer to the device's 

Hardware Installation Manual

2.

 

AC POWER:

 Insert the female connector that is located on one end of the AC power cord (supplied) into 

the device's AC power socket, located on the rear panel. Insert the male plug that is located on the 

other end of the AC power cord into a standard electrical wall outlet.   

 

3.

 

DC POWER: 

Connection to mains power of -48V must be made by trained or instructed service 

personal. For connection to the device, use the supplied DC terminal block (supplied) in conjunction 

with 18-AWG wires, paying attention to correct polarity (as indicated by the 

+

 and 

 labels on the 

chassis, above the DC inlet). Secure the wires by fastening the screws located above them in the 

terminal block. Insert the DC terminal block plug into the DC inlet, located on 

the rear panel. Connect the DC power leads to a 48V DC power source. Use a 

DC rated 5A circuit breaker in series with the -48V wire as a disconnect 

device. 

 

When power is received by the device, the 

Ready

 LED that is located on the front panel is lit green. 

Summary of Contents for MediaPack 124

Page 1: ...nd Hardware Installation Manual respectively which can be downloaded from AudioCodes website at https www audiocodes com library technical documents Before you begin please read the Safety Precautions...

Page 2: ...ringing Red On Line malfunction SRTP is enabled and device resources DSPs are currently unavailable for calls on these ports their resources are borrowed for SRTP functionality This LED state applies...

Page 3: ...ults Disconnect the Ethernet cable and then with a paper clip or any other similar pointed object press and hold down the button for at least 12 seconds but no more than 25 seconds Mounting the Device...

Page 4: ...ated on one end of the AC power cord supplied into the device s AC power socket located on the rear panel Insert the male plug that is located on the other end of the AC power cord into a standard ele...

Page 5: ...a crossover RJ 45 Ethernet cable connect the device s Ethernet port that is located on the rear panel and labeled ETHERNET to the LAN port of your computer 2 Change the IP address of your computer to...

Page 6: ...Gateway in dotted decimal notation 7 Click Submit to apply your settings 8 Open the Maintenance Actions page Maintenance tab Maintenance menu Maintenance Actions and then click BURN to save your sett...

Page 7: ...FXS lines are first disconnected from the device Installation of the device must be in accordance with national electrical codes and conform to local regulations AC Power Use only the supplied AC powe...

Page 8: ...treet Airport City Lod 7019900 Israel Tel 972 3 976 4000 Fax 972 3 976 4040 AudioCodes Inc 200 Cottontail Lane Suite A101E Somerset NJ 08873 Tel 1 732 469 0880 Fax 1 732 469 2298 Contact us https www...

Reviews: