Version 5.8
41
July 2009
Installation Manual
2. Physical Description
The PS module provides LEDs on its front panel, as described in the table below.
Table
2-21: PS AC Power Supply LEDs Description
LED
Color
Status
Description
FAULT
Yellow
On
Power supply failure.
--
Off Normal
operation.
POWER
Green
On
Power is supplied to the blade.
--
Off
No power is supplied to the blade.
2.9.2
DC Power System
The DC power system is powered by two DC sources (providing 1+1 power redundancy)
and consists of the following hardware components:
Power Entry Module (PEM/DC/3K)
Power Supply Module (PS/DC/3K)
Warnings:
•
Use two separate DC power sources for power redundancy to avoid total
power failure in case one of the DC power sources fails.
•
When using DC power as the primary input, ensure that the output is
SELV as defined by the safety standard requirements CAN/CSA-C22.2
No. 60950-1UL 60950-1, and EN 60950-1.
The table below lists the device's DC power specifications.
Table
2-22: DC Power Supply Specifications
Parameter
Value
Power Requirements
40 to 60 VDC
Power Consumption
IPmedia 3000:
9
IPM-6310 Simplex:
5.25 A @ 48 VDC, 252W
Mediant 3000 with TP-8410:
9
16 E1/T1 Simplex:
3A @ 48 VDC, 145W
9
16 E1/T1 HA:
4.4A @ 48 VDC, 212W
9
63 E1/84 T1 Simplex:
4.6A @ 48 VDC,2234W
9
63 E1
/
84 T1 HA:
7.2A @ 48 VDC, 343W
Connection Provisions
PEMs with input block terminals
Summary of Contents for IPmedia 3000
Page 1: ...Document LTRT 94704 July 20009 Installation Manual Version 5 8...
Page 2: ......
Page 8: ...Installation Manual 8 Document LTRT 94704 Mediant 3000 IPmedia 3000 Reader s Notes...
Page 12: ...Installation Manual 12 Document LTRT 94704 Mediant 3000 IPmedia 3000 Reader s Notes...
Page 90: ...Installation Manual Version 5 8 www audiocodes com...