Controls and operation on the front side  

 
 
The frontside of the Eklipse has a number of controls, whose function should be  elaborated upon. We start from the left  
 
The left selectorswitch balances the outputs and allows you to MUTE the amplifier or put it on STAND BY. The five LEDs 
under the knob indicate the chosen setting, each possible setting has its own LED.  
When the outermost left LED is lit permanently, the device is in STAND BY mode, e.g. the tubes are heated up but no 
anodecurrent is passed through them. Simultaniously the outputs of the amplifier are muted, which is represented by the 
lighting of the orange LED for MUTE, next to the red LED for STAND BY. The STAND BY position is remote controllable. 
 
When you turn the left selectorswitch ONE POSITION to the right, you mute the amplifier. This is represented by the second 
LED from the left. The LED is orange and it bli nks to underline the MUTE position the amplifier is in. When muted, the 
outputs are shorted to prevent signal leaving the amplifier. The MUTE position is remote controllable as well.  
 
When switched on, the amplifier is allways in MUTE during the first minu te. This prevents powerspikes that may be caused 
by the large magnetic coils to reach the outputs. When the safe MUTE period is over the amplifier is ready for use.  
 
When you select the centre position with the selectorswitch, output 1 is selected as the f unctioning amplifier output, this is 
represented by the green centre LED of the five. The slection of functioning  outputs is available through the selectorswitch 
only, the remote control doesn’t allow you to select this option. The balanced XLR output is  always switched on, regardless 
of the slected cinch output.  
  
Position four of the selectorswitch selects output 2 as the functioning output, a second green LED shows you you’ve selected 
this option.  
 
The fifth (and last)  setting of the selectorswitch a llows outputs 1 and 2 to function simultaneously. 
 
Just as a reminder: The outputs can only be selected through the selectorswitch. 
 
On the righthand side of the outermost left selectorswitch, another selectorswitch allows you to select seven different inp ut 
devices, each represented by seven green LEDs. 
The first LED from the LED corresponds with the most left input, which is CD1. The next LED is for the next input, etc. 
maximum of seven devices can be used as input devices with the Eklipse Pre -Amplifier. 
 
If you turn the knob into the eighth position (no LED lighting up), you activate the remote controled selection of input 
devices. 
 
There is a nineth position you can select with the second selectorswitch. This activates a generator which mechanically cleans 
all relais in the Eklipse Pre-Amplifier. When selecting ths option, turn down the volume completely first and disconnect your 
power amplifier before switching to the nineth position. The mechanical usage of the connectors through the generator 
prevents the buildup of oxidation on the contacts. We advise you perform this cleansing of the contacts approximately 10 
minutes per week. 
 
The cleansing option is available through the selectorswitch only. 
 
 
 
 
 
 
 
 
 
 
 
 
Both remaining switches on the righthand sid e serve volume control and ballance adjustments.  
Volume can be changed through both the controlswitch and the remote control. Underneath the volume control a red LED 
aknowledges the receipt of signal from the remote conrol. Secondairy to this function, the  LED is a control mechanism for 
the proper functioning of the remote control. 
The balance is meant as fine -tuning between both stereo channels only, the maximum adjustment lies / - 3 dB. It is 
not meant to serve as a means to switch one of the channels off completely. The fine-tuning of channels can not be performed 
with the remote control. 
 
 

Summary of Contents for Eklipse

Page 1: ...ements in mind It was made to allow you many years of musical joy AUDIO VALVE guarantees that this amplifier has been produced under the strictest of guidelines and with respect for procedures acquired through decades of tube amplifier design Your Eklipse Pre amplifier has been thoroughlytried and tested in all detail I personally guarantee the quality of this product H Becker Manager Production D...

Page 2: ...afeguard maximum functionality and to avoid operating problems it is important that you carefully study this owners manual and that you follow all instructions therein precisely General information Important instructions reagrding safety securety and operational reliability while using the Eklipse Pre Amplifier are highlighted throughout this manual 2 Herstellernachweis Factoryaddress AUDIO VALVE ...

Page 3: ...ier Alwayscheck powercords and plugs for damage before use Disconnect the powercord before work is being done on the amplifier In the unlikely case of a failure of the device repairs may be performed by AUDIO VALVE authorized technicians only Use ORIGINAL spare parts only Please take note of the fact that we waive product liability for damages caused bij our devices parts and components as a resul...

Page 4: ...to other components it might be damaged if t his is done with the amplifier under power The person operating the amplifier might be hurt as well in this case since powerspikes operating currents and voltage chargesmay occur Check whether the ON OFF switch is in the OFF position Ifso you can now plug in the powercord Use high quality cables only Usage of DIY cables low spec cables or cables intende...

Page 5: ...ning output a second green LED shows you you ve selected this option The fifth and last setting of the selectorswitch allows outputs 1 and 2 to function simultaneously Just as a reminder The outputs can only be selected through the selectorswitch On the righthand side of the outermost left selectorswitch another selectorswitch allows you to select seven different inp ut devices each representedby ...

Page 6: ...ngles underwhich the amplifier will be able to receive a signal from the remote control The amplifier can only be switched on and off through the switch on the front of the amplifier Zusammengefasst noch mal die Funktionen der manuellen und fernbedienbaren Möglichkeiten A short overvieuw of the options both manually and with the remote control STAND BY manually and remote control MUTE manually and...

Page 7: ...ly relay the positive sourcesignal the negative source or negative contact of these XLR outputs is connected to the amplifiers mass This type of XLR is also known as FAGE output Netx to the XLR outputs you ll find the Cinch RCA outputs that provide the output signal of this Pre Amplifier The contents of the signal being relayed ca be determined by the outermost righthand selector switch on the fro...

Page 8: ...xittubes are much less demanding when it comes to quality When you think the AC current enteringyour amplifier is out of phase with the amplifier you might considder switching both wires under the tripolar connector on the upper righthand side Thus you reverse the AC flow and therewith the polarity Never do this when the amplifier is still connected to the mains Please considder having having this...

Page 9: ...open the batery cover on the back of the RC Change the bateries and close the cover Make sure the batteries are placed in the right polarity When you have questions regarding the change of batteries please consult your vendor or give us a call The M2R and IR2R function identically except for the absence of a remote control with the M2R The RC functions are taken care of by brass selectors on the M...

Page 10: ...ch the volume off the Eklipse is SILENT Please note both the minimal background noise and the equaly low input noise level the Eklipse Pre Amplifier scored in tests That is no mean feat Like all AUDIO VALVE amplifiers the Eklipse has been designed to be a timeless p iece a high closs powder coated 4mm thick lasercut steel with gilded connectors That concludes the basic technical description of the...

Page 11: ...e with this manual Abuse accidental damage or unauthorized modifications as determined by AUDIO VALVE or its agents exclusively Removal defacing or falsifying of the serial numbers Shipping without the original complete factory crat es WARRANTY REGISTRATION Please fill out and return this warranty form to the US distributor within 15 days of the purchase date MODEL ________________________________...