System 10 Portable Camera-Mount Wireless
Installation and Operation
2
wireless microphones have low-power transmitters (less than 0.05 watts output) which are unlikely
mic transmitter typically is placed against the body, we suggest attaching it at the belt, rather than
in a shirt pocket where it may be immediately adjacent to the medical device. Note also that any
medical-device disruption will cease when the RF transmitting source is turned off. Please contact
your physician or medical-device provider if you have any questions, or experience any problems
with the use of this or any other RF equipment.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
9. Unplug this apparatus during lightning storms or when unused for long periods of time.
10.
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
CAUTION on handling receiver battery
•
crush, modify, disassemble, heat above 140°F (60°C) or incinerate.
•
replace battery on your own.
•
clean water.
• If the battery leaks and the liquid contacts your eyes, immediately wash thoroughly with
clean water and seek medical assistance.
•
• Charge battery only with the supplied AC adapter and USB cable.
Thank you for choosing an Audio-Technica professional wireless
have chosen our products because of their quality, performance and
reliability. This wireless microphone system is the successful result of
years of design and manufacturing experience.
Audio-Technica’s System 10 Portable Camera-Mount is a digital wireless
system designed to provide rock-solid performance along with easy
setup and clear, natural sound quality. Featuring a compact design,
System 10 Portable Camera-Mount is available in handheld, lavalier
from TV and DTV interference, System 10 Portable Camera-Mount
offers extremely easy operation and instantaneous channel selection.
Up to eight channels may be used together without any frequency
coordination problems or group selection issues.
System 10 wireless ensures clear communications by providing three
levels of diversity assurance: frequency, time, and space. Frequency
Diversity sends the signal on two dynamically allocated frequencies
for interference-free communication. Time Diversity sends the signal
in multiple time slots to maximize immunity to multipath interference.
Finally, Space Diversity uses two antennas on each transmitter and
receiver to maximize signal integrity.
Each System 10 professional digital wireless system includes a receiver
and camera shoe mount, and either a body-pack transmitter or a
handheld microphone/transmitter.
Because System 10 packaging is designed to hold all versions of
the system, some compartments in the carton may be intentionally
left empty.
The ATW-R1700 receiver includes a switching power supply that
automatically adapts to changes in mains voltage.
The versatile ATW-T1001 UniPak
®
body-pack transmitter has both a high-
impedance input for instruments, and a low-impedance input with bias
connection for use with dynamic and electret condenser microphones.
The ATW-T1002 handheld transmitter features a unidirectional dynamic
microphone element.
Both the body-pack and handheld transmitters use internal AA batteries
and have Power/Mute switches and input Trim (level) adjustments.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE SCREWS. NO
USER-SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THE APPLIANCE TO
RAIN OR MOISTURE.
CERTIFICATION:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. THIS DEVICE COMPLIES
WITH INDUSTRY CANADA LICENSE-EXEMPT RSS STANDARD(S). OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
Cet appareil est conforme à la/aux norme(s) CNR exempte(s) de licence d’Industrie Canada. Son
fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer
d’interférence et (2) cet appareil doit accepter toutes les interférences, y compris celles susceptibles de
provoquer un fonctionnement non souhaité.
WARNING:
the user’s authority to operate this equipment.
RF Exposure Statement:
This transmitter must not be co-located or operated in conjunction with any
other antenna or transmitter.
The ATW-R1700 complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS-102 of the IC radio
frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it deemed to
comply without maximum permissive exposure evaluation. (MPE). But it is desirable that it should be
installed and operated keeping the radiator at least 20cm or more away from person’s body.
Le ATW-R1700 conforme aux limites d’exposition aux rayonnements énoncées pour un
environnement non contrôlé et respecte les règles d’exposition aux fréquences radioélectriques
(RF) CNR-102 de l’IC. Cet équipement émet une énergie RF très faible qui est considérée conforme
sans évaluation de l ’exposition maximale autorisée. Cependant, il est souhaitable qu'il devrait être
installé et utilisé en gardant une distance de 20 cm ou plus entre le dispositif rayonnant et le corps.
low power wireless devices. There is no proof, however, that these low power wireless devices are
absolutely safe. Low power Wireless devices emit low levels of radio frequency energy (RF) in the
microwave range while being used. Whereas high levels of RF can produce health effects (by heating
tissue), exposure of low-level RF that does not produce heating effects cause no known adverse health
effects. Many studies of low-level RF exposures have not found any biological effects. Some studies
additional research. ATW-T1001, ATW-T1002 has been tested and found to comply with FCC/IC radia
-
tion exposure limits set fourth for an uncontrolled environment and meets the FCC radio frequency (RF)
Exposure Guidelines and RSS-102 of the IC radio frequency (RF) Exposure rules.
micro-ondes lorsque' ils sont utilisés. Alors qu' une dose élevée de RF peut avoir des effets sur la
santé (en chauffant les tissus), l' exposition à de faibles RF qui ne produisent pas de chaleur n' a pas
de mauvais effets connus sur la santé. De nombreuses études ont été menées sur les expositions
aux RF faibles et n' ont découvert aucun effet biologique. Certaines études ont suggéré qu' il pouvait
supplémentaires. ATW-T1001, ATW-T1002 a été testé et jugé conforme aux limites d' exposition aux
rayonnements énoncées pour un environnement non contrôlé et respecte les règles les radioélectriques
(RF) de la FCC lignes directrices d'exposition et d' exposition aux fréquences radioélectriques (RF)
CNR-102 de l' IC.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-
Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil umerique de la classe
B est conforme a la norme NMB-003 du Canada.
CAUTION!
service personnel. No userserviceable parts inside. Do not expose to rain or moisture. The circuits
inside the receiver and transmitter have been precisely adjusted for optimum performance and
compliance with federal regulations. Do not attempt to open the receiver or transmitter. To do so will
void the warranty, and may cause improper operation.
Danger of explosion if battery is replaced incorrectly. If battery dies, send receiver to Audio-
recycling—do not throw away receiver as its battery contains toxic materials.
Notice to individuals
with implanted cardiac pacemakers or AICD devices:
Any source
of RF (radio frequency) energy may interfere with normal functioning of the implanted device. All