Preparation for use
15
1
4
Return the tonearm to the tonearm rest.
Setting tracking force
1
While supporting the counterweight so that it does not move, turn the tracking force gauge ring so
that its “0” position lines up with the centerline on the back of the tonearm.
The tracking force is not adjusted simply by turning the tracking force gauge ring.
1
1
Tracking force gauge ring
2
Turn the counterweight and the tracking force gauge ring counterclockwise (to the left) to set the
tracking force to the recommended tracking force value for the cartridge you are using.
Refer to the cartridge maker’s specifications for the recommended tracking force value.
The tracking force value for the cartridge provided with this product is 2.0 g.
Setting the anti-skate adjustment
While the record is playing, a force acts on the stylus tip to pull it inward. This force can be counteracted by setting the
same values for anti-skate and the tracking force.