Audio Authority 1173BK Installation And Operation Manual Download Page 8

8    Audio Authority Model 1173BK User Manual

Source Mode Installation

In this mode the unswitched audio channels of the six AVAtrix system A/V sources 

are provided as inputs to the audio distribution system. The Model 1173BK is there-

fore not associated with any one Model 1176BK, so only one 1173BK is necessary 

even when there are multiple 1176BKs in the system as shown in the table.

The AVM-562 architecture allows up to five expanders. Using Source Mode, the 

maximum number of Cat 5 zone outputs is 30 (shown) with one 1173BK installed.

1.  Install the Model 1173BK anywhere in the AVAtrix stack and set its address dial 

to the “M” position.

2.  Connect the desired audio outputs, which represent the six AVAtrix A/V sources, to audio input channels on the audio 

distribution system. 

3.  Audio system infrared outputs, if present, are intended to control its input sources. Plug a stick-on IR emitter into 

each of the audio system’s IR output jacks and apply the emitter to the corresponding A/V source. In this way, source 

control commands originating in each room are routed by the audio system via infrared to the relevant source. See 

below for more information about using RF control systems. 

IR Signal Routing

In Source Mode, the A/V sources and zone volume are generally controlled via IR through the audio distribution system 

keypad / IR receiver in each zone. The AVAtrix IR commands must be routed through a separate IR receiver connected 

to the AVAtrix Cat 5 receiver, necessitating two IR receivers in rooms with both A/V Cat 5 receivers and distributed audio 

service. To program IR remotes, download AVAtrix IR codes from www.audioauthority.com/page/software or obtain the 

codes from your remote control manufacturer. The AVAtrix may be used with any of five Cat 5 receiver styles. Models 

9878 and 9879 and 9880 dual Cat 5 receivers feature an IR pathway and analog audio, and 1180R and 1180RD do not.

Using RF Control Systems

If desired, use the RS-232 connection for source switching and volume control, utilizing the 1173BK ExpressRamp volume 

control (see page 10). The RF base station should generally be located near the AVAtrix. It may be to advantage to use 

Model 1111 to inject IR commands from the RF base station zone outputs into the Cat 5 pathways to simplify program-

ming. See Model 1111 manual for details.

Source Mode User Instructions

Depending on the installation, you will use a wall-mounted controller or an infrared or wireless controller to select which 

music from various audio-only or audio/video sources you wish to enjoy. Your installer will have connected the AVAtrix 

system and your whole-house or room audio system to work together, enabling you to bring the pictures and sound you 

desire to each location in your home.

Model AVM-562

(Address A)

Model 1176

Address B

Model 1176

Address C

Model 1176

Address D

Model 1176

Address E

Model 1173BK

Address M

Summary of Contents for 1173BK

Page 1: ...ne Audio Router with Volume Control for the HD Cat 5 Matrix Routing System 701 12442B Manufactured in the USA by Audio Authority Corporation Lexington Kentucky 800 322 8346 or 859 233 4599 www audioau...

Page 2: ...audioauthority com 800 322 8346 859 233 4599 Warnings To reduce the risk of fire or electric shock do not expose this unit to rain or moisture The exclamation point symbol alerts users to important op...

Page 3: ...m with the video program being received on a Cat 5 zone receiver The 1173BK responds to IR or RS 232 commands from programmable control systems to attenuate volume levels on individual analog outputs...

Page 4: ...Cat 5 output row The diagram on the facing page shows a basic system for six zones but an expanded system for 12 or 18 zones would be configured as shown in the table The AVM 562 architecture allows...

Page 5: ...utput 1 so that the audio always matches the video at the zone Address each 1173BK to match the AVAtrix outputs see page 4 A Cat 5 1173BK 18V Power Supplies to Power Strip Address A IR Remote Control...

Page 6: ...1 2 3 4 5 6 Stereo Speakers Variable Audio Output IR Receiver IR Receiver AVR 1 AVR 3 L R L R L R L R Tracking Mode Diagram 2 A V Receivers as Zone Amplifiers In this configuration dedicated A V rece...

Page 7: ...L C L R Volume Control Signals 9879 9879 Sub IR IR SUB Speaker Wire Coax IR Receiver Tracking Mode Diagram 3 Digital AVRs as Zone Amplifiers with Volume Control In this configuration dedicated AVRs ar...

Page 8: ...iver in each zone The AVAtrix IR commands must be routed through a separate IR receiver connected to the AVAtrix Cat 5 receiver necessitating two IR receivers in rooms with both A V Cat 5 receivers an...

Page 9: ...Power Supplies to Power Strip Address M IR Remote Control Audio Distribution System with Integrated Switching Located in Equipment Closet Audio Input for Source 1 Zone 1 Output to Zone 1 Speakers IR...

Page 10: ...uter device in range A F In this document braces and are used to signify ONE of the enclosed characters For example L U indicate either of the two characters L or U General Commands Extended Command R...

Page 11: ...e level of all zones of 1173BK tracking A V router x V Im Im V vvv Query volume level of source m valid when 1173BK is in source mode V I I1 V vvv I2 V vvv I3 V vvv I4 V vvv I5 V vvv I6 V vvv Query vo...

Page 12: ...ive unit to constitute a valid in warranty claim Units that fail after the warranty period has expired may be returned to the factory for repair at a nominal charge if not damaged beyond the point of...

Reviews: