Audio Authority Model 1173BK User Manual 11
Query Commands (Extended)
Query:
Response:
Description:
[?,C,Rx,On]
(Rx,On,Im)
Query zone connection
[?,R,Rx,On]
(Rx,On,R,V,t)
Query zone restriction status. (see note)
[?,C,M]
(M,Im)
Query main connection
[?,C,X]
(RA,O1,Im) (RA,O2,Im)
(RA,O3,Im) (RA,O4,Im)
(RA,O5,Im) (RA,O6,Im)
(RB,O1,Im) (RB,O2,Im)
(RB,O3,Im) (RB,O4,Im)
(RB,O5,Im) (RB,O6,Im)
…through all devices
(M,Im)
Query all connections
[?,R,X]
(RA,O1,R,V,300) (RA,O2,Im)
(RA,O3,Im) (RA,O4,Im)
(RA,O5,Im) (RA,O6,Im)
(RB,O1,Im) (RB,O2,Im)
(RB,O3,Im) (RB,O4,Im)
(RB,O5,Im) (RB,O6,Im)
…through all devices
(M,Im)
Query restriction status of all zones (see note)
[?,C,RA]
(RA,O1,Im) (RA,O2,Im)
(RA,O3,Im) (RA,O4,Im)
(RA,O5,Im) (RA,O6,Im)
Query connections of all zones on A/V router x
[?,R,RA]
(RA,O1,R,V,300) (RA,O2,Im)
(RA,O3,Im) (RA,O4,Im)
(RA,O5,Im) (RA,O6,Im)
Query restriction status of all zones on A/V router x (see note)
[?,V,Rx,On,vvv]
(Rx,On,V,vvv)
Query volume level of zone n of 1173BK in tracking mode
[?,V,Rx]
(Rx,O1,V,vvv) (Rx,O2,V,vvv)
(Rx,O3,V,vvv) (Rx,O4,V,vvv)
(Rx,O5,V,vvv) (Rx,O6,V,vvv)
Query volume level of all zones of 1173BK tracking A/V router x
[?,V,Im]
(Im,V,vvv)
Query volume level of source m (valid when 1173BK is in source mode)
[?,V,I]
(I1,V,vvv) (I2,V,vvv) (I3,V,vvv)
(I4,V,vvv) (I5,V,vvv) (I6,V,vvv)
Query volume level of all sources (valid when 1173BK is in source mode)
[?,V,X]
(RA,O1,V,vvv) (RA,O2,V,vvv)
(RA,O3,V,vvv) (RA,O4,V,vvv)
(RA,O5,V,vvv) (RA,O6,V,vvv)
(RB,O1,V,vvv) (RB,O2,V,vvv)
(RB,O3,V,vvv) (RB,O4,V,vvv)
(RB,O5,V,vvv) (RB,O6,V,vvv)
…through all devices
Query volume level of all zones of all 1173’s in tracking mode
[?,{L,U},P]
(P,{L,U})
Query status of panel lockout
[?,{L,U},I]
(I,{L,U})
Query status of internal I/R lockout
[?,{L,U},A]
(A,{L,U})
Query status of AutoSelect lockout
[?,{+,-},B]
(B,{+,-})
Query status of Display blanking
[?,{+,-},P]
(P,{+,-})
Query status of Display Screen
All valid commands are listed in the tables above.
If the AVAtrix receives any other string in brackets
[
and
]
it is identified
as an invalid command and the AVAtrix responds with the message
(ERROR)
.
Note:
When a zone is restricted, its input is set to a non-valid input number. If a user tries to restrict video or control of a
zone that is not on a valid input, the AVAtrix returns the input number to alert the programmer that the restriction was not
performed. Example: (Rx,On,I7).