background image

5

Introduction 

Professional DAB/DAB+ & FM tuner

The DSP40 is a professional DAB/DAB+ & FM tuner which provides access to a wide variation of radio 
stations while guaranteeing a high-quality audio reproduction. Station selection can be done manually 
or automatically, while up to 10 preferred channels can be internally stored and recalled.

The front panel of the system accommodates a 2.8” TFT display in combination with a push rotary 
function dial and 4 tactile push buttons. The controls and indicators on the front panel of the unit are 
guaranteeing an intuitive and user friendly operation, allowing hassle free operation and configuration to 
even unexperienced users. Information such as radio station information carried by RDS / Radio text and 
signal reception strength are indicated.

The signal output level is user configurable while dynamic range compression (DRC) is supported, improving 
the intelligibility for low volumes in applications with high levels of background noise.

Other functions such as mono/stereo (FM) switching always guarantee the best possible audio reception.

The antenna input is implemented by an F-type connector allowing connection of the included antenna 
cable or any other external antenna using 75

Ω

 coaxial cabling. The balanced stereo line output is connected 

through two 3-pin terminal block connections.

The RS-232 communication port allows system integration with any home or industrial automation system, 
while an optional 2.4 GHz remote control allows handheld control while hidden out of sight.

Summary of Contents for DSP40

Page 1: ...DSP40 User Manual www audac eu ...

Page 2: ...es a ground connection Substitute cords may not provide adequate fault protection Only use the power cord supplied with this product or an authorized equivalent replacement Safety notices Denmark Apparatets stikprop skal tilsluttes en stikkontakt med jord som giver forbindelse til stikproppens jord Finland Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan Norway Apparatet må tilkopl...

Page 3: ...EEE 7 Caution 7 Chapter 1 Pin connections and connectors 9 Connection standards 9 Chapter 2 Front rear panel 10 Front panel overview 10 Front panel description 10 Rear panel overview 11 Rear panel description 11 Chapter 3 Using the DSP40 12 Main screen 13 DSP40 settings 14 General settings 15 Chapter 4 Additional information 16 Technical specifications 16 ...

Page 4: ...4 ...

Page 5: ...sers Information such as radio station information carried by RDS Radio text and signal reception strength are indicated The signal output level is user configurable while dynamic range compression DRC is supported improving the intelligibility for low volumes in applications with high levels of background noise Other functions such as mono stereo FM switching always guarantee the best possible au...

Page 6: ...LEVELS OF DUST HEAT MOISTURE OR VIBRATION THIS UNIT IS DEVELOPED FOR INDOOR USE ONLY DO NOT USE IT OUTDOORS PLACE THE UNIT ON A STABLE BASE OR MOUNT IT IN A STABLE RACK ONLY USE ATTACHMENTS ACCESSORIES SPECIFIED BY THE MANUFACTURER UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME ONLY CONNECT THIS UNIT TO A MAINS SOCKET OUTLET WITH PROTECTIVE EARTHING CONNECTIO...

Page 7: ... Do not get the unit wet If liquid is spilled on the unit shut it off immediately and take it to a dealer for service Disconnect the unit during storms to prevent damage WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE The WEEE marking indicates that this product should not be disposed with regular household waste at the end of its life cycle This regulation is created to prevent any possible harm t...

Page 8: ...8 ...

Page 9: ...R Pin 2 Right Ground XLR Pin 1 For balanced line output connections For unbalanced line output connections RS232 serial connection interface For connection with home automation systems or other remote control equipment Connection Standard RS232 PIN 2 DSP40 TX PIN 3 DSP40 RX PIN 5 GND Settings 19200 Baud 8 Bit 1 Stop bit No parity No Handshaking RS232 The complete command set for controlling the DS...

Page 10: ...and user friendly browsing through the menu structure The functionality of the four tactile push buttons on the left side depends on the current mode and position in the menu structure Icons on the left side of the display are indicating the current functionality linked with the buttons Parameter adjustment and browsing is made easy using the rotary function dial This multifunctional dial allows e...

Page 11: ...lete RS232 command instruction set and configuration information can be downloaded from the AUDAC website USB Update Connection The USB Update connection can be used for system firmware updates and or for connection of the RF remote control RMT40 receiver Balanced stereo line output The balanced stereo line output is implemented using two 3 pin terminal block connectors The audio output available ...

Page 12: ...mode and position in the menu structure Icons on the left side of the display are indicating the current functionality linked with the buttons The rotary selection dial can be used for parameter adjustments and browsing to station lists playlists or any other This multifunctional dial allows easy one hand operation throughout the entire menu structure Browsing is done by rotating it while actions ...

Page 13: ...playing program or track name More information such as signal reception strength the number of available DAB radio stations and the bitrate of the currently playing station is shown on the right side of the screen FM DAB switching Switching between DAB and FM mode is done by pressing the FM DAB FM DAB button The current mode FM or DAB is shown on the display in front of the tuning frequency or sta...

Page 14: ...ngle pressing the function dial DAB DRC The DRC Dynamic Range Compression increases the loudness of the signal in the quieter parts of the audio signal and decreases it in the louder parts This technique allows quite parts of the audio signal still being audible in situations with high background noise without blasting out It can be switched between Off Low and High DRC data is carried by an addit...

Page 15: ... or never always on making the backlight of the LCD automatically turn off after the set time Password Password protection can be enabled avoiding unauthorized users to make any adjustment to the system The password is a four digit code In default the password is set to 0000 which gives full access to the system without requiring any password to be entered If the configured password is different f...

Page 16: ...12 5 kHz Crosstalk 1 kHz 26 dB DAB Tuning Range 10 dB Band 3 171 240 MHz L Band 1452 1492 MHz Sensitivity 1W 1m 99 dBm Signal Noise 81 dB THD N 1 kHz 0 026 Frequency Response 3 dB 42 Hz 20 kHz Crosstalk 1 kHz 53 dB Outputs Type Balanced stereo line outputs 3 pin Euro Terminal Block Pitch 3 81 mm Level 8 dB 32 dB Power Consumption 0 7 W Dimensions W x H x D 482 x 44 x 330 mm Weight 3 150 kg Mountin...