background image

PT100M Installation Guide 

Version 1.0 

Auber Instruments, 730 Culworth Manor, Alpharetta, GA 30022 

e-mail: 

[email protected]

         Tel: 404-291-6298 

www.auberins.com 

(This guide was extracted and modified from the Installation Guide for the PID Retrofitting 
Kit for Rancilio Silvia. Full instruction will be provided to the kit buyer) 

Procedure 

 Installation in boiler compartment 

 

 

Fig 1, top view of original wiring. Red arrows indicate where the controller power cable 
will be tapped. Green arrow points to brew water control thermostat. Blue arrow points 
to steam temperature control thermostat. 

 
1)

 

There are two thermostats on top of the boiler. The one on the left with a red dot on top is 
the brew water temperature control thermostat. The one on the right is for controlling the 
steaming temperature. You need to remove the cable connectors on both side of brew 
water temperature thermostat (connectors with red and gray cable). They need to be 
connected to the output cable of SSR (after the RTD sensor installation). You also need 
to remove this thermostat and move the steaming thermostat to its position. This is 
because you need to mount the RTD sensor to the thermowell underneath the steam 
temperature control thermostat. This thermowell is closer to the cold water inlet, and 
results in better control. You need to use a small to medium sized flat head screw driver 
to remove the screw. Be very careful to not let it drop into the gap below. A magnetized 

Reviews: