TI044
1/4
TI044
Installation and User Guide
Industrial Indoor/Outdoor Solar Timer
• Provides normally-open (NO) dry contacts to independently
control two loads:
•
Load 1
follows a user-programmed schedule when placed in
automatic mode. The load can also be activated or
deactivated manually similar to the operation of a regular
switch. A single-pole switch can be connected to the timer to
control Load 1 similar to a 3-way installation. For example,
the timer can be installed outside whereas the switch can be
located remotely (e.g., inside the house).
•
Load 2
always follows the sunset/sunrise program; i.e., it is
activated at sunset and deactivated at sunrise. It is usually
used for night lighting.
• Can be used in various applications (see table below)
Cut power at the main electrical panel to avoid electric shock.
Open the TI044 door and remove the plastic cover to access the
mounting holes and wire terminals.
Install the TI044 to a vertical surface such as a wall by means of
three screws (not supplied).
WARNING: To prevent rain infiltration or any other liquid from
the top, the TI044 must be installed in the upright position as
shown above.
Remove the necessary knockouts at the bottom of the housing.
Install strain-relief bushings over the knockouts, pass the wires
through the bushings and secure them in place.
Perform the connections as shown on the wiring diagram.
NOTE: For a 3-way installation only, connect a regular single-
pole switch to the 3-way terminals of the timer as shown on the
wiring diagram.
Reinstall the plastic cover and apply power at the main electrical
panel.
3.1
First power-up
At power-on, 0:00 should flash. Otherwise, press
reset
using a paper
clip. If the display is blank, verify the power supply.
3.2
Load 1
Load 1 can operate in Manual or Automatic mode. To switch between
the two modes, press and hold the
MODE
button for 3 seconds.
Manual Mode
In Manual mode, the TI044 operates like a regular switch to control
Load 1. Briefly press the
MODE
button to activate or deactivate the
load. (If you have connected a remote switch to the timer for a 3-way
installation, the switch can also be used to activate or deactivate
Load 1.) The mode indicator (
MAN
)
and the state (
ON
or
OFF
) are
displayed.
About your new timer
1.
Load type
Maximum load
Examples
Resistive load
3600 W
(30 A @ 120 V)
•
incandescent lights
•
halogen lights
•
block heaters
Inductive load
1200 W
(10 A @ 120 V)
•
fluorescent lights
•
compact fluorescent lights (CFL)
•
sodium lamps
•
electronic ballasts
Motor
1.5 hp @ 120 V
•
pumps
•
fans
Installation
2.
Knock-out
Operation
3.
manual or
automatic
operation
night
lighting
120 V
power
supply
Single-pole switch
(for 3-way installation)
• Briefly press the button
to turn the load On or Off
(applies to Load 1 only).
• Press the button for 3
seconds to switch
between Automatic
mode and Manual mode
(applies to Load 1 only).
Mode display
(applies to Load 1 only)
On/Off display
(applies to Load 1 only)
Program number
sunset/sunrise program
Insert a paperclip
to reset the timer.