background image

TH232-AF-230

      400-232-003-B                    2010-05-26                    4/4

Customizing the schedule

You can program the thermostat to use either 2 or 4 periods
each day. 

For example, you can use 4 periods on weekdays and 2

periods on weekends. If you want to use 2 periods, choose periods “1
and 4” or periods “2 and 3”. Early Start will not work if you choose
periods “1 and 2” or periods “3 and 4”.

Press 

Pgm

. Period 1 of Monday is displayed.

If you wish to select another day, press 

Day

 repeatedly until the 

desired day is displayed.

NOTE

: To select all 7 days, hold the 

Day

 button for 3 seconds. 

This function is helpful if you want the same program every day. 
When all 7 days are selected, the start time of the displayed 
period will be applied to all 7 days.

If you wish to select another period, press 

Pgm

 repeatedly until 

the desired period is displayed.

Press 

Hour

 and 

Min

 to set the period start time.

NOTE

: To skip the period, press 

Clear

. The thermostat will 

display --:-- to indicate that the period will not be used.

To program another period, go back to step 2.

Press 

Mode/Return

 to exit.

NOTE

: If no button is pressed for 60 seconds, the thermostat will

save the changes and return to normal display.

7.2

Manual Mode 

In manual mode, the programmed schedule is not
used. Use this mode if you wish to set the temperature
manually or keep the same temperature all the time.
To use the manual mode:

Press the 

Mode

 button to display  .

Set the temperature using the 

 buttons or 

select one of the preset temperatures by pressing 
the  

or  

button.

Supply

: 230 VAC, 50 Hz

Maximum Load

: 15 A or 3450 Watts (NI)

Rated Impulse

: 2500 V

Ambient temperature 

setpoint range (A/AF models)

: 5 °C to 30 °C (40 °F to 86 °F)

Floor temperature 

setpoint range (F model)

: 5 °C to 40 °C (40 °F to 104 °F)

Floor temperature 

limit range (AF model)

: 5 °C to 40 °C (40 °F to 104 °F)

Temperature display range

: 0 °C to 70 °C (32 °F to 158 °F)

Temperature display resolution

: 0.5 °C (1 °F)

Operating temperature

: 0 °C to 50 °C (32 °F to 120 °F)

Storage temperature

: -20 °C to 50 °C (-4 °F to 120 °F)

Heating cycle length

: 15 minutes

Software

: Class A

Automatic action

: Type 1B and 1Y 

Protection index

: IP21

Conformity

: EN60730-1 / EN50081-1 / EN50082-2

Protection

: Class 2

Environment

: Normally polluted

Power outage

: All programs and temperature settings are saved

during a power outage. The clock must be reprogrammed if the
power outage lasts more than 4 hours. When power returns, the
thermostat returns to the mode of operation preceding the outage.

Aube warrants this product, excluding battery, to be free from defects
in the workmanship or materials, under normal use and service, for a
period of three (3) years from the date of purchase by the consumer. If
at any time during the warranty period the product is determined to be
defective or malfunctions, Aube shall repair or replace it (at Aube's
option).
If the product is defective,
(i)

return it, with a bill of sale or other dated proof of purchase, to the
place from which you purchased it, or 

(ii) contact Aube. Aube will make the determination whether the

product should be returned, or whether a replacement product
can be sent to you.

This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Aube that the defect or
malfunction was caused by damage which occurred while the product
was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE
OF THIS PRODUCT. Some provinces, states and regions do not
allow the exclusion or limitation of incidental or consequential
damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR
DURATION OF THIS WARRANTY. Some regions do not allow
limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from one province, state or region to another.

705 Montrichard 
Saint-Jean-sur-Richelieu 
Quebec, Canada  J2X 5K8
Tel: 1-800-831-AUBE
Email: [email protected]

For more information on our products, go to 

www.aubetech.com

Technical Specifications

8.

Warranty

9.

Technical Assistance

10.

400-232-003-B (Aube TH232-AF-230-OEM) ENG.fm  Page 4  Wednesday, May 26, 2010  1:51 PM

Summary of Contents for TH232-AF-230

Page 1: ...t the base covers the electrical box entirely If not install a wall plate at the back of the base Connect the wires Power Terminals 1 5 Load Terminals 2 4 see note 1 Pilot Wire Terminal 3 see note 2 Floor sensor Terminals 6 7 no polarity see note 3 WARNING Ensure that the wires are tightly secured to the terminals Apply a minimum torque of 0 5 Nm 4 4 Lb in when tightening the screws Note 1 If a co...

Page 2: ...it and save the changes NOTE If no button is pressed for 60 seconds the thermostat will save the changes and return to normal display 4 2 Other Configurations This procedure allows you to choose the following configurations Press and hold the Pgm button for 3 seconds The current tem perature unit is displayed unit Press the to toggle between C and F Press the Pgm button briefly The current time fo...

Page 3: ...2 preset temperatures Comfort temperature Economy temperature To use a preset temperature press the corresponding button The corresponding icon will be displayed The following table shows the intended use and the default value of each of the preset temperatures To store a preset temperature Set the desired temperature using the buttons Press and hold the corresponding temperature preset button unt...

Page 4: ... settings are saved during a power outage The clock must be reprogrammed if the power outage lasts more than 4 hours When power returns the thermostat returns to the mode of operation preceding the outage Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the co...

Reviews: