Aube Technologies TH115-AF-024T Owner'S Manual Download Page 13

Owner’s Guide

12

ENG

LISH

WARNING

: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor tempera-

ture limits.

The minimum and maximum floor temperature limits are 5.0°C (41°F) and 28.0°C (82°F) by default.
To modify these limits, proceed as follows:

n

Switch the thermostat to Off.

o

Press and hold the 

 button.

p

Switch the thermostat back to On.

q

Release the

 button when the minimum temperature limit (

FL:LO

) appears.

r

Set the minimum temperature limit using the 

 buttons.

s

Press the 

 button to display the maximum temperature limit (

FL:HI

).

t

Set the maximum temperature limit using the 

 buttons.

u

Press 

Mode/Ret

 to return the thermostat to normal display.

NOTE

: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Floor temperature limits (AF mode only)

400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book  Page 12  Monday, April 12, 2010  3:10 PM

Summary of Contents for TH115-AF-024T

Page 1: ...Owner s Guide TH115 AF GA TH115 AF GB Programmable thermostat 400 115 051 B ...

Page 2: ... Floor temperature limits 12 Preset temperatures 13 Default schedule 14 Modifying the schedule 15 Operation Running the schedule Automatic mode 16 Temporary override of schedule 16 Permanent override Manual mode 17 Before going on vacation Vacation mode 17 Ground fault protection GFCI 18 Appendices Error messages 20 Technical specifications 21 Customer assistance 22 Warranty 23 Table of contents 4...

Page 3: ...exposed to water or rain To prevent severe shock or electrocution always turn the power Off at the service panel before working with wiring Install the thermostat onto an electrical box Use special CO ALR solderless connectors if you connect the thermostat to aluminum wires Keep the thermostat s top and bottom air vents openings clean and unobstructed at all times Before you start 400 115 051 B Ho...

Page 4: ...onnectors for copper wires One 1 floor sensor One 1 flat tip screwdriver About your thermostat A mode controls the ambient air temperature F mode controls the floor temperature using an external temperature sensor AF mode controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 E...

Page 5: ...r button Hour button Minutes button Place at Off to cut power to the heater e g in the summer This will not affect the time and temperature settings When the backlight button or either of the buttons is pressed the display illuminates for 12 seconds TEST light button for ground fault protection see page 18 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS book Page 4 Monday April 12 2010 3 10 P...

Page 6: ...rol mode see pages 3 9 Ground fault indicator see page 18 Day The thermostat normally displays the actual measured temperature To view the setpoint temperature briefly press either of the buttons The setpoint will appear for 5 seconds To change the setpoint temperature press one of the buttons until the desired temperature is displayed To scroll faster press and hold the button 400 115 051 B Honey...

Page 7: ...e page 8 r If you wish to connect a remote control device see page 8 s Install the wallplate to the electrical box using the provided screws t Set the configuration switches on the back of the faceplate see page 9 u Install the faceplate back on the wall plate and tighten the screw v Apply power to the heating system w Test the ground fault protection see page 19 Installing the thermostat Wallplat...

Page 8: ...olderless connectors for copper wires Wiring diagram White 120 V Load Power supply Red Black Red Red Black Black Red Black 240 V Load Power supply Red Black Red Black Black Black White 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS book Page 7 Monday April 12 2010 3 10 PM ...

Page 9: ... between two floor heating wires for best temperature control Do NOT staple the sensor head the plastic end to the floor Doing so might damage the sensor Any damage might not be noticeable during testing but can become apparent several days later o If you wish to connect a remote control device see page 17 insert the wires use 18 to 22 gauge flexible wires through one of the two openings on the wa...

Page 10: ... disabled off heating starts only at the beginning of periods 1 and 3 thus there is a delay before the Comfort temperature is reached Enable Disable 3 Temperature control mode2 2 See page 3 To select the F Mode place the switch in the F position To select the AF Mode place the switch in the AF position and ensure that the temperature sensor is connected to the thermostat To select the A Mode place...

Page 11: ... minutes p Press the Day button to set the day q Press the Mode Ret button to return the thermostat to normal display NOTE The thermostat will automatically return to normal display if no button is pressed for 60 seconds Time and day 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS book Page 10 Monday April 12 2010 3 10 PM ...

Page 12: ...ns to toggle between On enabled and Off disabled p Press the Day button briefly The year setting is displayed q Press either of the buttons to set the current year r Press the Day button briefly The month setting is displayed s Press either of the buttons to set the current month t Press the Day button briefly The date setting is displayed u Press either of the buttons to set the current date v Pr...

Page 13: ...stat back to On q Release the button when the minimum temperature limit FL LO appears r Set the minimum temperature limit using the buttons s Press the button to display the maximum temperature limit FL HI t Set the maximum temperature limit using the buttons u Press Mode Ret to return the thermostat to normal display NOTE The thermostat will automatically return to normal display if no button is ...

Page 14: ...o modify a preset temperature n Press one of the buttons to display the desired temperature o Press and hold the appropriate preset temperature button or until its icon is displayed Preset temperatures Preset temperature Intended use Icon A AF modes F mode Comfort When at home 21 0 C 70 F 28 0 C 82 F Economy When asleep or away from home 17 0 C 63 F 20 0 C 68 F Vacation During prolonged absence 10...

Page 15: ...se the following combinations 1 and 4 or 2 and 3 Early Start see page 9 will not work with any other combinations You can have a different program every day i e each period can start at a different time every day The thermostat has been programmed with the following schedule Default schedule Period Description Setting MO TU WE TH FR SA SU Wake Comfort 6 00 6 00 6 00 6 00 6 00 6 00 6 00 Leave Econo...

Page 16: ...ek q Press Hour and Min to set the period start time or press Clear to skip cancel the period will be displayed r Repeat steps 2 to 4 to program another period s Press Mode Ret to return the thermostat to normal display NOTE The thermostat will automatically return to normal display if no button is pressed for 60 seconds Modifying the schedule 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS b...

Page 17: ...erature by pressing the or button when the thermostat is in Automatic mode the new temperature will be used until the beginning of the next period flashes during the temporary override You can cancel the temporary override by pressing Mode Ret Running the schedule Automatic mode Temporary override of schedule 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS book Page 16 Monday April 12 2010 3 ...

Page 18: ...ctivated this way the icon appears on the screen without flashing From any remote control device equipped with a dry contact When the contact closes the thermo stat is placed in Vacation mode and the icon flashes on the screen All buttons on the thermostat are locked When the contact opens the thermostat returns to the previous mode NOTE When the Vacation mode is activated from a remote control de...

Page 19: ...or heating mat can cause a ground fault A ground fault protection thermostat does not protect against circuit overloads short circuits or electrical shocks For example you can still receive an electrical shock if you touch bare wires while standing on a non conducting surface such as a wood floor Ground fault protection reset When the ground fault protection mechanism trips the TEST light is On re...

Page 20: ...place the thermostat If the TEST light turns on continue the test p Switch the thermostat to Off then back to On If the TEST light turns off the test has passed Set the thermostat back to the desired tempera ture The test is now completed If the TEST light remains on the test has failed Continue with the rest of the procedure q Switch the circuit breaker at the service panel of the heating system ...

Page 21: ...ay range Heating is activated The measured temperature is above the display range Heating is deactivated Verify the thermostat connection and sensor connection Error Messages 400 115 051 B Honeywell TH115 AF GA_GB 5 x 3 125 EFS book Page 20 Monday April 12 2010 3 10 PM ...

Page 22: ... settings are saved However the time and Daylight Saving Time must be set if the power failure lasts more than 6 hours The thermostat will return to the mode that was active prior to the power failure Technical Specifications Model Supply Max load resistive only Ground Fault Protection GFCI Wiring Current Power TH115 AF GA 120 VAC 60 Hz 15 A 1800 W 5 mA 4 wires double pole 240 VAC 60 Hz 3600 W TH1...

Reviews: