6

Glossary

fabric

A Fibre Channel switch or two or more Fibre Channel switches interconnected to physically 
transmit data between any two N_Ports on the switch or switches 

FC

Fibre Channel

F_port

A port in the Fibre Channel fabric where a N_port may attach

FL_port

A port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop

frame

an indivisible unit for transfer of information in Fibre Channel

frame header

the first field in the frame containing the address and other control information about the frame

full duplex

a communication protocol which allows transmission in both directions at the same time

half duplex

a communication protocol which allows transmission in both directions, but only one direction at a 
time

host

a processor, usually a CPU and memory, which communicates with devices over an interface

initiator device

A component which originates a command

L_port

a port in an arbitrated loop, either a NL_port or a FL_port

LED

Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs 
are used as indicator lights on all sorts of electronic devices

LUN

Logical Unit Number: an identifier for a logical unit (0-7)

multi-mode fiber

an optical fiber which can carry several beams of light at once 

N_port

a port attached to a node used with point to point or fabric configurations

NL_ port

a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration

originator

an initiating device; a component which originates a command

parity checking

A method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in 
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error 
message occurs if the sum is not correct

PCI

Peripheral Component Interconnect. Allows peripherals to be connected directly to computer 
memory, bypassing the slower ISA and EISA busses

point-to-point

a topology where two ports communicate

port

an access point in a device: see N_port, NL_port, etc.

port address

also port number; the address, assigned by the PCI bus, through which commands are sent to a 
host adapter board

port number

see port address

receiver

the ultimate destination of data transmission; a terminal device 

scatter/gather

a device driver feature which allows the host adapter to modify a transfer data pointer so that a 
single host adapter can access many segments of memory, minimizing interrupts and transfer 
overhead

SCSI

Small Computer Systems Interface: a processor-independent standard for system-level interface 
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers, 
scanners, etc. 

single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is 

nearly equal to the wavelength of the source

topology

logical layout of the parts of a computer system or network and their interconnections

transceiver

a transmitter/receiver module

transfer rate

the rate at which bytes or bits are transferred, as in megabytes or gigabits per second

Term

Definition

Summary of Contents for ATTO ExpressPCI FC 3321

Page 1: ...r SW optical LC SFP interface ATTO ExpressPCI FC 3342 Quad channel 2 Gigabit FC to PCI X Host Adapter SW optical LC SFP interface 2003 ATTO Technology Inc All rights reserved All brand or product name...

Page 2: ......

Page 3: ...Interface Advanced FC Features Advanced SCSI FCP Support Exclusive Advanced Data Streaming ADS Technology Accelerated PCI Bus Management Environmental Physical Specifications 2 Fibre Channel is a key...

Page 4: ...Appendix A Standards and compliances i Appendix B Fibre Channel accessories ii Appendix C SCSI host adapter selection guide iii Appendix D Contact ATTO Technology Inc iv...

Page 5: ......

Page 6: ...annel topologies Point to point Arbitrated loop Switched fabric FL port F port Strict adherence to ANSI specifications FC PH FC AL2 FC FCP FC PLDA FC FLA FCA IP iETF iPFC FC Tape Supports Class 2 and...

Page 7: ...CA IP iETF iPFC FC Tape Supports Class 2 and Class 3 transfers LEDs indicate link activity on line and fault status for each channel Flash ROM for easy field upgrades Advanced FC Features Support for...

Page 8: ...SI specifications FC PH FC AL2 FC FCP FC PLDA FC FLA FCA IP iETF iPFC FC Tape Supports Class 2 and Class 3 transfers LEDs indicate link activity on line and fault status for each channel Flash ROM for...

Page 9: ...nnel 400MB secper channel 400 MB sec 400 MB sec Class transfers 2 3 2 3 2 3 2 3 2 3 Full duplex 7 7 7 7 7 66 33 MHz PCI compatible 66 MHz only 7 7 7 7 133 MHz PCI X compatible 7 7 64 and 32 bit PCI co...

Page 10: ...Port from a collection of ports which ask for use of the arbitrated loop at the same time arbitrated loop a loop topology FC AL in which two or more ports are interconnected but only two ports can com...

Page 11: ...iguration originator an initiating device a component which originates a command parity checking A method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in the tra...

Page 12: ...ss is clearly marked on the back of the board for easy identification Please keep a reference copy of the number in a safe place or write in the space provided below ExpressPCI FC host adapter WWNs ar...

Page 13: ...should use 50 micron multi mode optical cables Cable length should be no more than 500 meters ExpressPCI FC 3342 The ATTO ExpressPCI FC 3342 has four pluggable SFP LC optical connectors and uses a sh...

Page 14: ...Installation and Operation Manual Exhibit 3 3 ExpressPCI FC 3322 bracket and board Exhibit 3 4 Express PCI FC 3342 bracket and board FC Controller ExpressPCI FC 3322 bracket and board ExpressPCI FC 3...

Page 15: ...excellent performance for a wide range of applications some specialized applications may benefit from modification of the adapter settings to tune the adapter for a specific performance range The Expr...

Page 16: ...r for my device option 4 Insert the ATTO ExpressPro Tools CD 5 In next window be sure the CD ROM is selected as the source for the driver 6 Once the system finds the driver click the Next button 7 Cli...

Page 17: ...e files to your desktop and install the Configuration Tool on your system 4 Launch the Configuration Tool 5 In the Device window select the adapter that needs to be updated 6 In the Flash window click...

Page 18: ...lled Follow the procedure in Chapter 4 All of the external devices connected to the host adapter should be identified If they do not appear in the Device Manager the external devices or connection may...

Page 19: ...in the loop should be identified If they do not appear in the Device List the external devices or connection are not working properly If the card has been recently re flashed with new firmware the new...

Page 20: ...o which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian standards This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num r...

Page 21: ...SCSI products are also available from ATTO Technology Please contact your ATTO sales representative for product descriptions and part number information Fibre Channel solutions FC Rack System Modular...

Page 22: ...lable and include an ExpressPCI SCSI host adapter ExpressRAID software and appropriate cable s Add KIT suffix to host adapter product code i e EPCI UL3D KIT Specific features Single Channel ExpressPCI...

Page 23: ...ern Standard Time 8 00 a m to 8 00 p m or by e mail and web site 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice 716 691 9353 fax http www attotech...

Reviews: