71
English
RAIS/
attika
- User manual for RAIS Q-Tee II
Q-TEE II on a 250 mm high log store
If the stove is to be installed on a wooden floor, it must be covered with a non-combusti-
ble material at least 12 mm thick, in accordance with UK Building Regulations Approved
Document J. The stove is to be elevated min. 250 mm, for example placed on a non-com-
bustable base.
Installation distance from combustible ceiling, floor and side wall
E
H
G
(m
in
. 2
50
)
Normal corner setting
Uninsulated flue / Insulated flue
Distance to flammable materials (min.)
E. to the side of the wall
400 mm
400 mm
G. to the floor
250 mm
250 mm
H. to the ceiling
800 mm
800 mm