70
English
RAIS/
attika
- User manual for RAIS Q-Tee II
B
E
E
A
D
D
Corner setting 45°
The stove is placed on a non-combustible floor.
Uninsulated flue
Insulated flue
Uninsulated flue
with Reflector
A. Distance to furniture (min.)
1200 mm
1200 mm
1200 mm
Distance to flammable materials (min.)
B. in front (floor)
575 mm
575 mm
575 mm
C. to the side (floor)
if distances are not shown,
national/local regulations are followed
D. to the rear (wall)
300 mm
200 mm
200 mm
E. to the side of the wall
400 mm
400 mm
400 mm
Q-TEE II on a 250 mm high log store
If the stove is to be installed on a wooden floor, it must be covered
with a non-combustible material at least 12 mm thick, in accordance
with UK Building Regulations
Approved Document J. The stove is to be elevated min. 250 mm, for
example placed on a non-combustable base.
Distance to flammable materials (min.)
B. in front (floor)
300 mm
300 mm
300mm