ATTACK PZO 120 Instructions For Use Manual Download Page 4

4

Chart No. 2: BASIC TECHNICAL DATA ON WATER STORAGE TANKS

Pict.No.1: Basic dimensions
of water storage tanks

Chart No. 1: BASIC DIMENSIONS OF WATER STORAGE TANKS

Waste gas breaker

Flue deflector

Hot water

Tank coating

 Polyurethan insulation

 Magnesium anodal bar

 Thermostat sleeve

 Main burner

 Gas valve

 Pilot-burner

 Hot water inlet

 Hot water outlet

80

5,3

55

0,56

85

0,56

TYPE

ATTACK PZ 80
ATTACK PZ 120

Volume

(L)

Power

demand

(kW)

Heating time

 t = 45°C

(min)

Gas consumption

3

(m /h)

5,3

104

5,3

ATTACK PZ 150

120

150

0,56

D

B

E

F

Type

ATTACK PZO   80

ATTACK PZO  120

ATTACK PZO  150

WEIGHT

(kg)

DIMENSIONS (mm)

D

A

B

C

E

F

575
880

1130

985

1240
1510

860

1155
1385

520
520
520

320
320
320

100
100
100

52
65
78

Summary of Contents for PZO 120

Page 1: ...W W W A T T A C K S K DIRECTHEATEDGASTANKSFORD H W ATTACK PZO INSTRUCTIONS FOR USE...

Page 2: ...PERATION 6 Procedure of filling the tank with water 6 Checking the tank before ignition 7 Start putting the appliance to operation 8 Regulation of water temperature 8 Putting the storage tank out of o...

Page 3: ...o operation the ignition flame is burned with the help of a piezoelectric lighter that burns the flame of the main burner Heat arising from gas burning is transferred through the bottom of the steel t...

Page 4: ...um anodal bar Thermostat sleeve Main burner Gas valve Pilot burner Hot water inlet Hot water outlet 80 5 3 55 0 56 85 0 56 TYPE ATTACK PZ 80 ATTACK PZ 120 Volume L Power demand kW Heating time t 45 C...

Page 5: ...ny CONNECTINGTHEHOTWATERSTORAGETANKTOGASPIPE The assembly must be done by valid standards and precautions On the inlet of gas to the appliance there must be a closing element gas valve that should be...

Page 6: ...ossible to connectitwithaflueflapelectricallycontrolled Although technically it is possible to fit a bimetal flue flap due to low total savings because of somenegativeguidingsigns firstofallhighernois...

Page 7: ...rature By a regulation button switch off temperature can be set up in the range of 40 70 C We recommend to set the regulation button to 4 5 position In this position we can reach the temperatureof55 6...

Page 8: ...e15seconds Closingtimeisabout45secondsbutitcannotovercome60seconds TESTOFTHEDEVICE Whenputtingthedevicetooperationtheorganizationisobligedtocheck safetytimesofflamefuse adjustmentoftheappliancetoacert...

Page 9: ...maintenance of the storage tank which can prolong life and ensures operation without failures To make repairs and maintenance possible and easy there must be free approach to the storagetank Airsuppl...

Page 10: ...Onlyforqualifiedworkers Adjustmentoftheoutletpressure All the adjustments must be done according to technical parameters of the appliance Inlet and outlet pressure are checkedbyAandBoutlets Maximum pr...

Page 11: ...afterthe2ndyearofoperation Stamp signature of the service organization Date Data of the customer legibly Name and surname Street ZIP code town Tel Devicecommissioningreport Serial number Date of commi...

Page 12: ...ceho upozor nenia ATTACK s r o producer reserves the right to change technical parameters and dimensions of boilers without previous warning Der Hersteller ATTACK s r o beh lt sich das Recht der techn...

Reviews: