ATTACK AK1000K Instruction Manual Download Page 4

D2

1 ½"

AS

RS

1 ½"

1 ½"

90°

45°

45°

4

ATTACK AK

ATTACK AS

ACCUMULATION TANKS ATTACK AK, AS

Summary of Contents for AK1000K

Page 1: ...THE ACCUMULATION TANKS ATTACK AK AS HR HRS TUV TUVS S SS INSTRUCTION MANUAL W W W A T T A C K S K...

Page 2: ...appliance is constructed for accumulation and subsequent distribution of the heat energy from the heat sourc es as well as for preparation of the D H W It is forbidden to use this appliance for other...

Page 3: ...he S and SS is a line of a stratified storage tanks with the volume up to 2 000 l and option to install the electrical heating body 2 2 Thermal insulation The accumulation tanks are supplied with 100...

Page 4: ...D2 1 AS RS 1 1 90 45 45 4 ATTACK AK ATTACK AS ACCUMULATION TANKS ATTACK AK AS...

Page 5: ...621 230 700 650 850 1 660 1 710 1 678 3 94 95 488 81 AK800K 1 545 1 135 725 315 840 790 990 1 840 1 890 1 864 3 108 95 732 109 AK1000K 1 735 1 255 775 295 840 790 990 2 030 2 080 2 052 3 127 95 915 1...

Page 6: ...1 2 3 EL EL 4 5 6 7 8 9 6 7 8 9 10 10 10 RS AS 10 10 10 10 10 1 2 3 4 5 AF AC MA CN 1 4 D2 D1 D1 R R 100 28 17 17 EL 28 6 ACCUMULATION TANKS ATTACK HR HRS ATTACK HRS ATTACK HR...

Page 7: ...4 8 Position 5 9 Position RS Position AS D1 Diameter without insulation D2 Diameter with insula tion of 100 mm Height Height with insulation of 100 mm R Slope dimension without insulation Max operatin...

Page 8: ...12 AC AF D2 8 ACCUMULATION TANKS ATTACK TUV TUVS TECHNICAL PARAMETERS OF THE D H W EXCHANGER Material Stainless steel Heated area 3 9 m2 Volume 13 l Connection 3 4 Max operating pressure 10 bar ATTACK...

Page 9: ...loss W Max operating pressure bar Area of exchanger m Volume of exchanger l Max operating pressure bar Max operatind tempera ture C Area of D H W exchanger m Volume l Weight kg TUV500K C 1 405 1 013 7...

Page 10: ...D2 1 1 1 90 10 10 45 45 10 ATTACK S ATTACK SS STRATIFIED STORAGE TANKS ATTACK S SS...

Page 11: ...insulation D2 Diameter with insulation of 100 mm Height Height with insulation of 100 mm R Slope dimension without insulation Max operating temperature C Static loss W Max operating pressure bar Area...

Page 12: ...to all inlets and outlets as it is given in the table in the chapter 3 Mount the deaeration valve at the highest place of the system and insulate all the connection distributions 5 2 Connection of th...

Page 13: ...ealing under the flange Maintenance of the accumulation tank HR HRS concerns test and replacement of the anode rod The magnesium anode adjusts the electric potential inside the tank to the value preve...

Page 14: ...and a suitable detergent Never use abrasive cleaners diluents petroleum based cleaners etc It is not necessary to clean the internal side of the tank because it is connected to the closed heating cir...

Page 15: ...15 ACCUMULATION TANKS Notes...

Page 16: ...8 61 Vr tky Slovakia Tel 421 43 4003 101 Fax 421 43 3241 129 E mail kotle attack sk Export tel 421 43 4003 103 Fax 421 43 3241 129 E mail export attack sk V robca ATTACK s r o si vyhradzuje pr vo tech...

Reviews: