ATTACK AK1000K Instruction Manual Download Page 11

11

ACCUMULATION TANKS

DESCrIPTION

ATTACK S

 – is based on the ATTACK AK type. Disk and stratified pipe 

installed  in  the  exchanger  enable  creation  of  water  layers  according  to 
the temperature. This construction ensures different temperature layers 
at the inlets and outlets.

ATTACK SS

 – is based on the ATTACK AS and the ATTACK S types. It is 

accessorized with an extra exchanger for connection to the solar circuit.

ATTACK S:

 10× socket G 1 ½", 5× socket G ½"

ATTACK SS:

 10× socket G 1 ½", 5× socket G ½", 2× socket G 1" – solar circuit

KEy fOr THE ACCUMULATION TANKS

1 – Flow connection – boiler .  .  .  .  .  .  .  .  .  .  .    1 ½"
2 – Freely disposable .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    1 ½"
3 – Electrical heating coil (EL)   .  .  .  .  .  .  .  .  .  .   1 ½"
4 – Freely disposable .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    1 ½"
5 – Return connection – heating circuit .  .  .  .    1 ½"
6 – Flow connection – heating circuit (radiators)   1 ½"
7 – Flow connection – heating circuit (floor) .    1 ½"
8 – Return connection, gas, oil or pellet boiler   1 ½"

9 – Return connection – wood boiler   .  .  .  .  .   1 ½"
10 – Sensor of solar system or heating    .  .  .  .  .  . ½"
AS – Flow connection of solar system  .  .  .  .  .  .  .  1"
RS – Return connection of solar system .  .  .  .  .  .  1"
SF – Upper solar sensor  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . ½"
SU – Bottom solar sensor  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . ½"
D1 – Diameter without insulation
D2 – Diameter with insulation

TECHNICAL PArAMETErS

Tank

Solar  

exchanger

Tank

Ty

p

En

er

gy e

ffi

cie

nc

y c

la

ss

Po

sit

io

n 1

–6

Po

sit

io

n 2

–7

Po

sit

io

n 3

L – m

ax

. le

ng

th o

f t

he e

le

ct

ric 

he

at

in

g b

od

y

Po

sit

io

n 4

–8

Po

sit

io

n 5

–9

Po

sit

io

n S

U

Po

sit

io

n S

F

Po

sit

io

n R

S

Po

sit

io

n A

S

 D

1 – D

ia

m

et

er w

ith

ou

in

su

la

tio

n

 D

2 – D

ia

m

et

er w

ith i

ns

ul

at

io

of 1

00 m

m

He

ig

ht

He

ig

ht w

ith i

ns

ul

at

io

n o

f 1

00 m

m

R – S

lo

pe d

im

en

sio

n w

ith

ou

in

su

la

tio

n

M

ax

. o

pe

ra

tin

g t

em

pe

ra

tu

re (

°C

)

St

at

ic l

os

s (

W

)

M

ax

. o

pe

ra

tin

g p

re

ss

ur

e (

ba

r)

Ar

ea o

f e

xc

ha

ng

er (

m

²)

Vo

lu

m

e o

f e

xc

ha

ng

er (

l)

M

ax

. o

pe

ra

tin

g p

re

ss

ur

e (

ba

r)

Vo

lu

m

e (

l)

W

ei

gh

t (

kg

)

S500K

C 1 405 1 013 871 700 621 230 461 1 209 -

-

650 850 1 680 1 730 1 698 95

-

3

-

-

-

488 81

S800K

- 1 545 1 135 946 840 725 315 491 1 340 -

-

790 990 1 842 1 892 1 898 95 105 3

-

-

-

713 157

S1000K

- 1 735 1 255 1 036 840 775 295 577 1 495 -

-

790 990 2 031 2 082 2 081 95 121 3

-

-

-

891 172

S1250K

- 1 655 1 175 988 1 000 695 285 565 1 415 -

-

950 1 150 1 975 2 025 2 064 95 142 3

-

-

- 1 239 172

S1500K

- 1 755 1 345 1 072 1 050 820 375 653 1 545 -

- 1 000 1 200 2 100 2 150 2 160 95 161 3

-

-

- 1 420 265

S2000K

- 1 955 1 408 1 314 1 150 862 315 685 1 682 -

- 1 100 1 300 2 309 2 356 2 390 95 188 3

-

-

- 1 960 296

SS500K

C 1 405 1 013 871 700 621 230 461 1 209 230 710 650 850 1 680 1 730 1 698 95

-

3 1,8 11,9 10 488 81

SS800K

- 1 545 1 135 946 840 725 315 491 1 340 315 725 790 990 1 842 1 892 1 898 95 105 3 2,4 15,9 10

713 157

SS1000K

- 1 735 1 255 1 036 840 775 295 577 1 495 295 860 790 990 2 031 2 082 2 081 95 121 3

3 19,8 10

891 172

SS1250K

- 1 655 1 175 988 1 000 695 285 565 1 415 285 850 950 1 150 1 975 2 025 2 064 95 142 3

3 19,8 10 1 239 172

SS1500K

- 1 755 1 345 1 072 1 050 820 375 653 1 545 375 895 1 000 1 200 2 100 2 150 2 160 95 161 3 3,6 23,7 10 1 420 265

SS2000K

- 1 955 1 408 1 314 1 150 862 315 685 1 682 315 665 1 100 1 300 2 309 2 356 2 390 95 188 3 4,2 27,7 10 1 960 296

Summary of Contents for AK1000K

Page 1: ...THE ACCUMULATION TANKS ATTACK AK AS HR HRS TUV TUVS S SS INSTRUCTION MANUAL W W W A T T A C K S K...

Page 2: ...appliance is constructed for accumulation and subsequent distribution of the heat energy from the heat sourc es as well as for preparation of the D H W It is forbidden to use this appliance for other...

Page 3: ...he S and SS is a line of a stratified storage tanks with the volume up to 2 000 l and option to install the electrical heating body 2 2 Thermal insulation The accumulation tanks are supplied with 100...

Page 4: ...D2 1 AS RS 1 1 90 45 45 4 ATTACK AK ATTACK AS ACCUMULATION TANKS ATTACK AK AS...

Page 5: ...621 230 700 650 850 1 660 1 710 1 678 3 94 95 488 81 AK800K 1 545 1 135 725 315 840 790 990 1 840 1 890 1 864 3 108 95 732 109 AK1000K 1 735 1 255 775 295 840 790 990 2 030 2 080 2 052 3 127 95 915 1...

Page 6: ...1 2 3 EL EL 4 5 6 7 8 9 6 7 8 9 10 10 10 RS AS 10 10 10 10 10 1 2 3 4 5 AF AC MA CN 1 4 D2 D1 D1 R R 100 28 17 17 EL 28 6 ACCUMULATION TANKS ATTACK HR HRS ATTACK HRS ATTACK HR...

Page 7: ...4 8 Position 5 9 Position RS Position AS D1 Diameter without insulation D2 Diameter with insula tion of 100 mm Height Height with insulation of 100 mm R Slope dimension without insulation Max operatin...

Page 8: ...12 AC AF D2 8 ACCUMULATION TANKS ATTACK TUV TUVS TECHNICAL PARAMETERS OF THE D H W EXCHANGER Material Stainless steel Heated area 3 9 m2 Volume 13 l Connection 3 4 Max operating pressure 10 bar ATTACK...

Page 9: ...loss W Max operating pressure bar Area of exchanger m Volume of exchanger l Max operating pressure bar Max operatind tempera ture C Area of D H W exchanger m Volume l Weight kg TUV500K C 1 405 1 013 7...

Page 10: ...D2 1 1 1 90 10 10 45 45 10 ATTACK S ATTACK SS STRATIFIED STORAGE TANKS ATTACK S SS...

Page 11: ...insulation D2 Diameter with insulation of 100 mm Height Height with insulation of 100 mm R Slope dimension without insulation Max operating temperature C Static loss W Max operating pressure bar Area...

Page 12: ...to all inlets and outlets as it is given in the table in the chapter 3 Mount the deaeration valve at the highest place of the system and insulate all the connection distributions 5 2 Connection of th...

Page 13: ...ealing under the flange Maintenance of the accumulation tank HR HRS concerns test and replacement of the anode rod The magnesium anode adjusts the electric potential inside the tank to the value preve...

Page 14: ...and a suitable detergent Never use abrasive cleaners diluents petroleum based cleaners etc It is not necessary to clean the internal side of the tank because it is connected to the closed heating cir...

Page 15: ...15 ACCUMULATION TANKS Notes...

Page 16: ...8 61 Vr tky Slovakia Tel 421 43 4003 101 Fax 421 43 3241 129 E mail kotle attack sk Export tel 421 43 4003 103 Fax 421 43 3241 129 E mail export attack sk V robca ATTACK s r o si vyhradzuje pr vo tech...

Reviews: