11 

 
Duress User Settings 

 

 
Wiegand Mode Setting 

 

There are 10 groups Duress PIN/card available. When input Duress PIN/card, the door will open, at the 
same time, the output alarm operates.

 

To set Duress PIN User

 

 To add a PIN user

 

1   3  user ID number  #  PIN   #

 

 To delete a PIN user

 

As the same method of deleting common PIN user

 

(The ID number is any number between 2101~2110.)

 

To set Duress card user

 

To add a card user by read card

 

1   3  read card 1  #  read card 2 …  #

 

(The ID number is any number between 2101~2010.)

 

To add a card user by card number

 

1   3  user ID number  #  card  …  #

 

(The ID number is any number between 2101~2010.)

 

To delete a card user

 

As the same method of deleting common card user

 

To delete

 All 

Duress

 users

 

Note that this is a 

dangerous

 option so 

use with care

 

2   3   0000   #

 

Note:

 

① User ID number must be any 4digits between 2101 ~ 2110

 

① Duress PIN/card must be unique, should be distinguished from common PIN/card

 

(When the Duress PIN/card is the same with common PIN/card, they will become invalid in Duress, and 

worked as common user function)

 

KZ-700-U/H

 supports Wiegand 26~37, both input and output. It can be used as a reader or controller.

 

To Set Wiegand format:

 

9  26~37 #  (Default setting: Wiegand 26)

 

Change Zone 2 to Door Bell

 

(When no need to operate a second door, Zone 2 can be set to operate the Door Bell. The wiring is connect-
ing the door bell to COM2 and NO2. Press #, the keypad will send the signal to the door bell.

 

Zone 2

 

84   0   #   Factory default.

 

Door bell

 

84   1   #

 

To remove the alarm

 

To reset the Door Forced Open warning

 

Read valid card

 or 

Master Code #

 

To reset the Door Open Too Long warning

 

Close the door 

or 

 Read valid card

 or 

Master Code #

 

Summary of Contents for Kade KZ-700-U/H

Page 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 700 U H VERSION 1 0 ...

Page 2: ...s Controller Installation manual All rights reserved AAT HOLDING S A 2 1 Introduction 3 2 Features 4 3 Specifications 5 4 Controller installation 5 5 Controller wiring diagram 6 6 Detailed Programming Guide 8 CONTENTS ...

Page 3: ... the KZ 700 U H is waterproof and con forms to IP68 The KZ 700 U H supports up to 2 100 users in a card 4 8 digits PIN card PIN option and additional 10 groups Duress PIN card The built in card reader sup ports both EM HID 125 KHz frequency cards tags The KZ 700 U H has many extra features including Duress PIN card block enrollment Wiegand 26 37 bits interface and backlight keypad etc These featur...

Page 4: ...IN Read both 125KHz EM HID card PIN length 4 8 digits Pulse mode Toggle mode Wiegand 26 37 input output Can be worked as reader or controller Dual relay output for door opening door status detecting open door by button Card block enrollment With manager cards for adding or deleting card user easily Very low power consumption 25mA Backlight keypad Light and sound of keypad can be set Support door b...

Page 5: ... 10 90 RH Environment Conforms to IP68 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 37 input output Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions L128 x W82 x H28mm Net Weight 600 g Gross Weight 700 g Specifications Installation Remove the back cover from the keypad using supplied security screwdriver Drill 4 h...

Page 6: ...C 2 Relay2 NC Black White COM2 Relay2 COM Pink NO2 Relay2 NO Red AC DC 12 24V DC 12 18V AC Regulated Power Input Red Black AC DC 12 24V DC 12 18V AC Regulated Power Input Brown D_IN Door Contact Yellow OPEN1 Request to Exit Button of Zone 1 Yellow Black OPEN2 Request to Exit Button of Zone 2 Grey Alarm Alarm Negative White D1 Wiegand Input Output D1 Green D0 Wiegand Input Output D0 Black GND Negat...

Page 7: ...ges state which will not turn back until read card or input PIN again Reset to Factory Default To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM or HID cards the LED will turn in red means reset to factory default setting successful ly Of the two cards read the first one is Manager Add Card the second ...

Page 8: ...1 2 for Zone 1 or 3 2 2 for Zone 2 To add PIN users 1 1 User ID number PIN Zone 1 User ID 1 2000 1 2 User ID number PIN Zone 2 User ID 2001 2100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 1 User ID number 1 PIN User ID number 2 PIN Zone 1 1 2 User ID number 1 PIN User ID ...

Page 9: ...he card a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves User ID number Old PIN New PIN New PIN To dele...

Page 10: ... inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute Alarm output time To set the alarm output time 0 3 minutes 5 0 3 Factory default is 1 minute Door open detection setting To disable door open detection Factory default 6 0 To enable door open detection 6 1 Keypad Lockout Alarm Output options If there are 10 inva...

Page 11: ...r To delete All Duress users Note that this is a dangerous option so use with care 2 3 0000 Note User ID number must be any 4digits between 2101 2110 Duress PIN card must be unique should be distinguished from common PIN card When the Duress PIN card is the same with common PIN card they will become invalid in Duress and worked as common user function KZ 700 U H supports Wiegand 26 37 both input a...

Page 12: ......

Reviews: