Aqua Treatment Service ©2013 • www.aquat.com
7
Con guration Settings
Step 1CS –
Press
V
and
W
buttons simultaneously for 5 seconds and release. If screen in Step 2CS does not
appear, the lock on the valve is activated. To unlock press
W
, NEXT, REGEN,
V
in sequence, then press
V
and
W
buttons simultaneously for 5 seconds and release.
Step 2CS –
Choose 1.0 for 1”, 1.25 for 1.25”, 1.5 for 1.5”, 2.0L for 2L, 2.0 for 2” valve ¹. Press NEXT to go
to Step 3CS. Press REGEN to exit Con guration Settings.
Note: When using the WS2 valve, if “2L” is set instead on “2.0” for valve type, when the valve is in
regeneration and the piston drives to the “Draw” cycle the piston will stall and generate a 1002 error code.
Clear error code by pressing “NEXT” and “REGEN” simultaneously until the valve resets, then re-program
to proper valve type setting.
Step 4CS –
Press the
V
or
W
buttons to select to regenerate immediately on 0 or at delayed time.
Immediately on 0 can only be selected if Volume (gallons) was selected in step 3CS and a meter must be
installed. Delay is the only option for the other Step 3CS selections. Press NEXT to go to Step 5CS. Press
REGEN to return to previous step.
Step 1CS
Step 2CS
Step 3CS –
Press the
V
or
W
buttons to select one of the following:
• If Volume (gallons) is selected the regeneration will occur after the speci c volume has been used or on the
day override (if selected) whichever comes rst.
• If 28/Volume (gallons) is selected the regeneration will occur on the day (1 through 28) selected in Installer
Display Settings. If a meter is not used the total ow and ow rate user displays and the volume display in
Diagnostics will be shown as 0.
• If 7/Volume (gallons) is selected the regeneration will occur on the selected day(s) of the week (see
instructions contained in Installer Display Settings). If a meter is not used the total ow and ow rate user
displays and the volume display in Diagnostics will be shown as 0.
• If 28 is selected the regeneration will occur on the day (1 through 28) selected in Installer Display Settings.
The total ow and ow rate user displays and the volume display in Diagnostics will not be shown even if a
meter is used.
• If 7 is selected the regeneration will occur on the selected day(s) of the week (see instructions contained in
Installer Display Settings). The total ow and ow rate user displays and the volume display in Diagnostics
will not be shown even if a meter is used.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
Step 4CS
¹ When using the WS2 control valve, the circuit board software must have meter selection choices
of 2.0 and 2.0L. The WS2 valve must be set for the 2.0 meter selection during programming. If the
software version does not have both the 2.0 and 2.0L selections, consult your equipment supplier
for a replacement circuit board. When using the WS2L valve with older version software that does
not have both 2.0 and 2.0L selection choices, the valve must be set to 2.0 during programming. If a
WS2L valve is being used with newer version software that has both 2.0 and 2.0L selection choices,
the valve must be set to 2.0L during programming.
Step 3CS
Control Valve cont:
Summary of Contents for TTV1EEM-3T
Page 2: ...Aqua Treatment Service 2013 www aquat com...
Page 16: ...Aqua Treatment Service 2013 www aquat com 14 Parts Breakdown...
Page 17: ...Aqua Treatment Service 2013 www aquat com 15 Parts Breakdown cont...
Page 19: ...Aqua Treatment Service 2013 www aquat com 17 Parts Breakdown cont...
Page 22: ...Aqua Treatment Service 2013 www aquat com 20 Parts Breakdown cont...