ATS TTV1EEM-3T Installation, Operation And Maintenance Manual Download Page 29

Aqua Treatment Service ©2013     •      www.aquat.com

27

Problem

Possible Cause

Solution

13. Water running to drain

a. Power outage during regeneration

a. Upon power being restored control will 

fi nish the remaining regeneration time. 
Reset time of day. 

b. Damaged seal/ stack assembly

b. Replace seal/ stack assembly

c. Piston assembly failure

c. Replace piston assembly

d. Drive cap assembly not tightened in 

properly

d. Re-tighten the drive cap assembly

14. E1, Err – 1001, Err – 101 = Control unable to 
sense motor movement

a. Motor not inserted full to engage pinion, 

motor wires broken or disconnected

a. Disconnect power, make sure motor is 

fully engaged, check for broken wires, 
make sure two pin connector on motor 
is connected to the two pin connection 
on the PC Board labeled MOTOR. Press 
NEXT and REGEN buttons for 3 seconds 
to resynchronize software with piston 
position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect.

b. PC Board not properly snapped into drive 

bracket

b. Properly snap PC Board into drive bracket 

and then Press NEXT and REGEN buttons 
for 3 seconds to resynchronize software 
with piston position or disconnect power 
supply from PC Board for 5 seconds and 
then reconnect.

c. Missing reduction gears

c. Replace missing gears

15. E2, Err – 1002, Err – 102 = Control valve motor 
ran too short and was unable to fi nd the next cycle 
position and stalled

a. Foreign material is lodged in control valve

a. Open up control valve and pull out piston 

assembly and seal/ stack assembly for 
inspection. Press NEXT and REGEN 
buttons for 3 seconds to resynchronize 
software with piston position or disconnect 
power supply from PC Board for 5 seconds 
and then reconnect.

b. Mechanical binding

b. Check piston and seal/ stack assembly, 

check reduction gears, check drive 
bracket and main drive gear interface. 
Press NEXT and REGEN buttons for 3 
seconds to resynchronize software with 
piston position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect.

c. Main drive gear too tight

c. Loosen main drive gear. Press NEXT 

and REGEN buttons for 3 seconds to 
resynchronize software with piston 
position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect.

d. Improper voltage being delivered to PC Board

d. Verify that proper voltage is being supplied. 

Press NEXT and REGEN buttons for 3 
seconds to resynchronize software with 
piston position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect.

Troubleshooting cont:

Summary of Contents for TTV1EEM-3T

Page 1: ...www aquat com Installation Operation and Maintenance Manual CAUTION Read and Follow all safety rules and operating instructions before first use of product DEALER NAME DEALER PHONE MODEL SERIAL DATE...

Page 2: ...Aqua Treatment Service 2013 www aquat com...

Page 3: ...ons 5 User Displays 6 Configuration Settings 7 9 Setting Regeneration Cycle Times 10 Installer Display Settings 11 12 Diagnostics 13 Parts Breakdown System 14 Control Valve 15 23 Specifications 24 Tro...

Page 4: ...stallation site of the equipment A drain must be available within 20 feet of the equipment Location of the equipment must be where it is not subject of freezing direct sunlight or room Temperature ove...

Page 5: ...alling systems Sanitary Sewer Line Cold Water Inlet Cold Water Outlet Valve Control Clean Water Tank Assembly System Drain Line Floor Drain Hard Water Line to Unsoftened Fixtures Direction of water fl...

Page 6: ...12V 1 V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 Drive Back Plate 1 EE Front Cover and Drive Assembly 1 4 6 5 3 2 AC Adapter U S International Supply Voltage 120 V AC 230V AC Supply Freque...

Page 7: ...edule a regeneration at the preset delayed regeneration time Pressing again and releasing will cancel the regeneration Pressing while in regeneration will advance to the next cycle Pressing in the pro...

Page 8: ...0 User 5 Shows current time Setting Time of Day Push NEXT button until time of day screen is displayed Press and hold the V or W arrow until the SET indicator is displayed and the hour ashes Press the...

Page 9: ...h 28 selected in Installer Display Settings If a meter is not used the total ow and ow rate user displays and the volume display in Diagnostics will be shown as 0 If 7 Volume gallons is selected the r...

Page 10: ...the feed water supply When set to nHbP the MAV will be driven closed before the rst regeneration cycle and be driven open after the last regeneration cycle NOTE If the control valve enters into an err...

Page 11: ...ed for an accumulative time of 2 minutes a regeneration will occur at the scheduled regeneration time HoLd If the dP switch is closed a regeneration will be prevented from occurring Not viewed if Step...

Page 12: ...length of the second backwash from 1 20 minutes using the or buttons Press NEXT to go to Step 6CT Press REGEN to return to previous step Step 6CT Adjust the length of rinse from 1 20 minutes using the...

Page 13: ...NEXT and V buttons simultaneously for ve seconds and release Step 2I Adjust days from 1 28 Press NEXT to go to Step 3I Press REGEN to exit Installer Display Step 3I Use V or W buttons to set time of...

Page 14: ...evious display 7 Day or 7 Volume Gallons selected in Con guration Settings Step 3CS Step 1I To enter Installer Display press the NEXT and V buttons simultaneously for 5 seconds and release Step 2I Use...

Page 15: ...curred Press NEXT to go to Step 3D Press REGEN to exit Diagnostics Step 3D Display shows the volume of water treated in gallons treated since the last regeneration If Volume gallons 28 Volume gallons...

Page 16: ...Aqua Treatment Service 2013 www aquat com 14 Parts Breakdown...

Page 17: ...Aqua Treatment Service 2013 www aquat com 15 Parts Breakdown cont...

Page 18: ...WS1 Piston Down ow ASY 1 4b V3011 01 WS1 Piston Up ow ASY 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O ring 215 Distributor Tube 1 Not Shown V3001 WS1 Body ASY...

Page 19: ...Aqua Treatment Service 2013 www aquat com 17 Parts Breakdown cont...

Page 20: ...fill Port Plug Asy This part is required for backwash only systems 2 H4615 Elbow Locking Clip 1 3 JCP P 6 Polytube insert 3 8 1 4 JCPG 6PBLK Nut 3 8 1 5 H4613 Elbow Cap 3 8 1 6 V3163 0 ring 019 1 7 V3...

Page 21: ...WS1 DLFC 1 0 gpm for V3162 013 WS1 DLFC 1 3 gpm for V3162 017 WS1 DLFC 1 7 gpm for V3162 022 WS1 DLFC 2 2 gpm for V3162 027 WS1 DLFC 2 7 gpm for V3162 032 WS1 DLFC 3 2 gpm for V3162 042 WS1 DLFC 4 2 g...

Page 22: ...Aqua Treatment Service 2013 www aquat com 20 Parts Breakdown cont...

Page 23: ...WS1 Split Ring 2 3 V3105 O Ring 215 2 4 V3189 WS1 Fitting 1 PVC Solvent 90 2 Order No V3007 02 Description WS1 Fitting 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 WS1 Nut...

Page 24: ...V3007 08 DESCRIPTION WS1 FITTING 1 1 4 PLASTIC MALE BSPT ASSEMBLY Drawing No Order No Description Quantity 1 V3151 WS1 Nut 1 Quick Connect 2 2 V3150 WS1 Split Ring 2 3 V3105 O Ring 215 2 4 V3361 WS1 F...

Page 25: ...tor 2 5 V3146 WS1 Bypass Cap 2 6 V3147 WS1 Bypass Handle 2 7 V3148 WS1 Bypass Rotor Seal Retainer 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 Not Shown Order No V3191 01 Descript...

Page 26: ...000 32 000 108 TTV1EEM 5T 9 275 9 22 1 10 x 54 30 000 48 000 140 H1071 02 SALT GRID 60 33 NOTES Overall Depth of Unit 24 All Dimensions are of the Unit only Size will very depending on plumbing used f...

Page 27: ...Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See Front Cover and Dri...

Page 28: ...Check for leaking xtures that may be exhausting capacity or system is undersized 10 Residual regenerant being delivered to service a Low water pressure a Check incoming water pressure water pressure...

Page 29: ...t power supply from PC Board for 5 seconds and then reconnect c Missing reduction gears c Replace missing gears 15 E2 Err 1002 Err 102 Control valve motor ran too short and was unable to nd the next c...

Page 30: ...function a Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to...

Page 31: ...d or reaffixing any ATS part or component thereof or be liable for any injury loss or damage direct or indirect special or consequential arising out of the use of misuse or the inability to use such p...

Reviews: