9
January 2004
GPT ARGUS
Bezel LED displays at normal operation
Idle State:
Validator is operational and ready to accept a bill.
• Each pair of green LEDs sequentially flash
at 4 Hz (Runway lights)
• Red LED is not lit
Accepting State:
A bill is inserted into the bill validator. The unit is
checking data to determine if the bill is valid.
• Green LEDs are not lit
• Red LED is not lit
Escrow-, Checking- and Rejecting State:
When the bill validator enters the escrow state,
stacking state or the rejecting state.
• All green LEDs are not lit
• The red LED is lit
Bezel LED displays error codes
Error - Malfunction:
1. A bill is inserted in the channel but does not
advance into the channel.
2. Stacker is not connected
3. Validator is in Inhibited Mode caused by an inhibit
command from the controller
• Green LEDs are not lit
• Red LED is lit
Bill jams in the channel:
Middle Sensor is covered - Front Sensor is active
• Fourth row of green LEDs is lit
• Red LED is lit
Bill jams in the channel:
Middle Sensor is covered - Front Sensor is not active
• Green LEDs are not lit
• Red LED is not lit
Stacker is jammed or full:
• Third row of green LEDs is lit
• Red LED is lit
V
ALIDATOR
H
ANDLING