Atrix OMEGA SUPREME PLUS VACOMEGAUM2F Instruction Manual Download Page 5

OPERATION INSTRUCTIONS 

 

1.

 

Release the two front fasteners and open the lid.  

2.

 

Remove hose and power cord from cover storage area. 

3.

 

Remove the orange plug from the filter cartridge and store in unit. 

4.

 

Slide one end of the hose into the filter cartridge. 

5.

 

Attach appropriate accessories on the hose assembly. 

6.

 

Plug the female end of the power cord into the receptacle on the vacuum. 

7.

 

Close lid and latch securely. 

8.

 

Plug the power cord into an appropriate outlet that is properly installed and grounded in 

accordance with all local codes and ordinances. 

9.

 

Turn on the power switch. 

10.

 

 These vacuums have a factory installed resettable Thermal Cutout (TCO) for added 

operator and motor safety.  If the unit gets too hot, the vacuum will shut down for 

approx. 40 minutes.  Turn the on/off switch to the off position, and turn back on in 

approximately 40 minutes.  Your hose may be clogged, or it may be time to install a new 

filter. 

11.

 

When vacuuming is complete, plug the filter with either the permanently attached filter 

plug or the disposable orange plug when storing and not in use. 

12.

 

The vacuum is equipped with a full filter indicator light underneath the switch/receptacle 

and is labeled “Full Filter”.  When the filter is nearing full capacity, the red light will turn 

on. 

13.

 

Filter Replacement:  Requires No. 1 Philips Screwdriver and Small Adjustable Wrench.  

Insert disposable filter plug.  Open Lid.  Remove metal filter retention bracket.  Lift out 

filter by putting fingers under each filter end tab and lift up and out.  Dispose of filter.  

Insert new filter.  Reattach metal filter retention bracket. 

 

FILTER CHANGE-OUT INSTRUCTIONS  

(Requires Phillips Screwdriver and Small Adjustable Wrench) 

 

1.

 

Release the two front latches and open the lid. 

2.

 

Insert small orange disposable filter plug contaminated filter cartridge. 

3.

 

Remove metal filter retention bracket. 

4.

 

Put fingers under each end of filter under filter tabs. 

5.

 

Lift up and out. 

6.

 

Dispose of full filter in an appropriate manner compliant with all local, state, and federal 

laws. 

7.

 

Insert new filter. 

8.

 

Reattach metal filter retention bracket. 

9.

 

Close Lid and latch securely. 

Summary of Contents for OMEGA SUPREME PLUS VACOMEGAUM2F

Page 1: ...N MANUAL Model VACOMEGAUM2F AC 230 V 50 60 Hz 450 Watts IEC EN 60335 2 69 Annex AA Class H Atrix 1350 Larc Industrial Blvd Burnsville MN 55337 www atrix com sales atrix com Telephone 952 894 6154 Toll Free Telephone 800 222 6154 Fax 952 894 6256 ...

Page 2: ...ing up hazardous debris without the use of the OF712UL Class H H14 filter installed WARNING This machine is for indoor use only CAUTION This machine is for dry use only CAUTION This machine shall be stored indoors only WARNING This machine shall be disconnected from its power source during cleaning and maintenance and when replacing parts or converting the machine to another function by removing t...

Page 3: ...ands 9 Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce airflow 10 Keep hair loose clothing fingers and all body parts away from openings and moving parts 11 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 12 Do not use without filter in place 13 Turn off all controls before u...

Page 4: ...screw WARNING THIS APPLIANCE IS INTENDED FOR COMMERCIAL USE ONLY SERVICING OTHER THAN NORMAL MAINTENANCE MUST BE DONE BY AN AUTHORIZED SERVICE REPRESENTATIVE USER INSTRUCTIONS THE USER OF THIS MACHINE MUST REFER TO THE APPLICABLE SAFETY REGULATIONS APPROPRIATE TO THE MATERIALS BEING HANDLED USER ADVISORY THE OUTSIDE OF THIS MACHINE SHOULD BE DECONTAMINATED BY VACUUM CLEANING METHODS AND WIPED CLEA...

Page 5: ...g the filter with either the permanently attached filter plug or the disposable orange plug when storing and not in use 12 The vacuum is equipped with a full filter indicator light underneath the switch receptacle and is labeled Full Filter When the filter is nearing full capacity the red light will turn on 13 Filter Replacement Requires No 1 Philips Screwdriver and Small Adjustable Wrench Insert ...

Page 6: ...dispose of your filter and drop in a new filter This vacuum is manufactured with long life motor brushes and will last for approximately 1 000 hours of use The motor brushes in this vacuum cleaner are not replaceable In 2002 the European Union introduced the Directive on Waste Electrical and Electronic Equipment WEEE The main aim of the Directive is to ensure that WEEE is collected and treated sep...

Page 7: ...EGAUM2F 50 60Hz 230V 450 Watts DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with ISO 4871 Operating mode 1 Operating mode 2 No load Normal Measured A weighted emission sound pressure level LpA ref 20 uPa at operator s position in decibels 72 76 72 67 Uncertainty KpA in decibels 2 2 Note The sum of a measured noise emission value and its associated uncertainty represents an upper bounda...

Page 8: ...TITLE AND AGAINST PATENT INFRINGEMENT ATRIX MAKES NO OTHER WARRANTIES WITH RESPECT TO THIS CUSTOM VACUUM CLEANER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Limitation of Liability ATRIX WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY COINCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OR ECONOMICAL LOSS BASED UPON BREACH...

Reviews: