33
139435_A GZ
455
DV 8/28/12
Figure 8.5. Wiring schematic, SIT Proflame 885 Burner Control System
Technical Data
Fan Control Module
Supply voltage/frequency: 120V, 60 Hz
Ambient temp. ratings:
32 to 140° F
Three wire bus: -Two wires provide DC voltage to
the Receiver
- One wire gives uni-directional
signal from the Receiver
Output voltage/frequency/current: 120V / 60 Hz / 5 A
Auxiliary switched output:
120V / 60 Hz / 2 A
Fan speed output:
120V / 60 Hz / 1 A
Remote Control Transmitter
Supply voltage: 4.5 V (three 1.5V AAA batteries)
Ambient temp. rating:
32 to 122° F
Radio frequency:
315 MHz
Receiver:
Supply voltage
6.0 V (four 1.5 AA batteries)
Ambient temp. rating:
32 to 140° F
Radio frequency:
315 MHz
CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING THE
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
ALWAYS VERIFY PROPER OPERATION AFTER
SERVICING THE APPLIANCE.
ATTENTION: AU MOMENT DE L’ENTRETIENDES
COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT
LE DÉBRANCHEMENT. DES ERREURS DE CÂBLAGE
PEUVENT ENTRAÎUN FONCTIONNEMENT
INADÉQUAT ET DANGEREUX.
See additional wiring diagrams in the Appendix on
page 38.