Foot Valve / Strainer
Product Specs
Product Specs
Cleaning & Sanitizing
Cleaning & Sanitizing External Surface Only
1. Cleaning: Wipe down or pressure wash external parts with mild stainless steel cleaner.
2. Sanitizing: Use sanitizers designed for stainless steel and plastic surfaces.
Cleaning & Sanitizing both Internally & Externally
1. Submersion (best method): Submerge entire assembly into a COP (Clean Out of
Place) vat for a standard parts cleaning proceedure. The openings in the top and bottom
of dispenser allow entire assembly to circulate and sanitize. (Use mild cleaning solutions
safe for EPDM and stainless steel at less than 125
o
F to protect suction tube. Standard
COP filler parts cleaning proceedure will apply.)
2. Pressure wash: If no COP tank is available the unit can be cleaned
using a standard pressure washer (1500 psi or less). The openings in the
top and bottom will allow access to internal parts.
3. Apply spray lube to working parts in the lower assembly.
Chemical Path Cleaning & Sanitizing
1. Rinse old solution from tubing and nozzle with clear water.
2. Fill sanitizer reservoir with hand sanitizer solution and pump
solution through. Suction tubing should be changed yearly or
when tubing shows signs of chemical attack. Tubing can
become stiff due to leeching of plasticizers from the tubing,
but this does not affect the function of the unit. Other tubing
can be substituted that more closely matches the chemistry
being used.
Nozzle assembly
(includes check valve)
To Clean Debris from Nozzle & Check Valve
1. Use the end of the tubing to unscrew the check
valve from the nozzle.
2. To remove debris from check ball, blow compressed
air in this direction ONLY (with no more than 5psi)
3. Check nozzle for debris before reinstalling check
valve. To reassemble, use the end of the tubing to
carefully screw the check valve back into the nozzle,
until the red poppit is showing slightly past the nozzle.
4. If the suction check valve needs to be replaced, be
sure to wrap a small amount of Teflon tape around the
threads before installation, taking care not to allow any
tape into the fluid stream.
Dispenser System Rebuild Kit (includes all wetted
parts and spare O-ring) available. Contact your
ATPGroup respresentative for details.
Suction Check Valve
(SS/EPDM)
2x O-Ring
(EPDM)
Suction Tube