TROUBLE SHOOTING
Before calling your serviceman, please make sure these simple checks:
If the unit is not operating:
1. Is the cabinet plugged in?
2. Is there a main-power failure?
3. Is there a blown fuse?
If the Fluorescent light is off:
1. Is the fluorescent light tube properly connected to the socket?
2. Dose the fluorescent light need to be changed?
If the cabinet temperature is too warm:
1. Is the thermostat set correctly?
2. Is the cabinet located in direct sunlight?
3.
Is the cabinet located in a strong air-flow path?
4.
Is the distance between the upper surface of the displayed merchandise and the
self directly above it at least 1”?
5. Is the unit away from the wall at least as 4”?
6. Is the air temperature around the cabinet above 75ºF?
Is there water in the door track or water leaking down the inside walls:
1.
Is the case level from side to side?
2.
Is the case level from front to back?
3.
Is the upper drain pan sagging?
Condensate drain is located in the center of the upper pan running down the center
channel along the back wall.