Atos Unify OpenScape Branch 550 Installation Manual Download Page 20

 

A31003-H8100-J100-01-7631, 09/2021 

20 

              OpenScape Branch 550 / 550HA, Installation Guide 

OSB 550HA

 

D44

 

1B433LF 

1A4B05F 

OSB 550HA

 

A44

 

4x FXO 

4x FXS 

1A4B02F 

1A4B05F 

OSB 550HA

 

DP14

 

1x E1 PRI 

4x FXS 

1TE131F 

1A4B05F 

OSB 550HA

 

DP24

 

2x E1 PRI 

4x FXS 

1TE235BF 

1A4B05F 

OSB 550HA

 

DP4

 

4x T1/E1 PRI 

NA 

1TE435BF 

OSB 550HA

 

DP8

 

8x T1/E1 PRI 

NA 

1TE435BF 

1TE435BF 

OSB 550HA

 

NC

 

NA 

NA 

 

2.3

 

OpenScape Branch 550 / 550HA variants 

Table below is a preliminary summary that includes all OSB 550 variants.  

The correct variant must be ordered to support FXO, FXS, BRI, E1/T1. 
 

Table 6: OpenScape Branch 550 /550HA Performance 

 

 

OSB 550 / OSB 550HA

 

Models 

D44  A44  DP14  DP24  DP4 

DP8 

NC

 

Max. supported number of SIP registered 
lines

1

 

500 

500 

500 

500 

500 

500 

500 

Max. number of concurrent sessions 

400 

400 

400 

400 

400 

400 

400 

Max. number of calls per second 
(continuous) 

Max. registrations per second (background) 

10 

10 

10 

10 

10 

10 

10 

Max. registrations per second (peak) 

500 

500 

500 

500 

500 

500 

500 

Max. number of concurrent announcement 
ports 

16 

16 

16 

16 

16 

16 

16 

Max. number of concurrent conference 
ports 

30 

30 

30 

30 

30 

30 

30 

Max. number of supported languages 

Max. number of backup ACD agents 

250 

250 

250 

250 

250 

250 

250 

Summary of Contents for Unify OpenScape Branch 550

Page 1: ...A31003 H8100 J100 01 7631 550 550 HA Installation Guide...

Page 2: ...6 1 7 Quality and Environmental Management 17 Disposal and Recycling 17 WEEE Compliance 17 1 8 Marking 17 The OpenScape Branch 550 550HA Overview 18 2 1 OpenScape Branch 550 550 HA 18 2 2 OpenScape Br...

Page 3: ...550HA Transportation 40 Technical Data 41 5 1 Block Diagrams 41 5 2 Standard Interfaces 42 Sangoma card TE130 Series TE131 TE132 TE133 TE134 42 Sangoma card TE430 Series TE435B TE435 TE436B TE4364 42...

Page 4: ...A31003 H8100 J100 01 7631 09 2021 4 OpenScape Branch 550 550HA Installation Guide History of Changes Issue Date Summary 1 09 2021 First issue of the guide...

Page 5: ...Professional Services and Back Level Support personnel Note that this does not preclude other Unify personnel customers or third party service providers who have the necessary prerequisite knowledge f...

Page 6: ...shocks when touching products or parts of products Failure to observe the precautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD...

Page 7: ...ivery Part Qty Part Description OpenScape Branch 550 OpenScape Branch 550HA 1 System configuration as ordered incl a 19 rack mounting set Rubber feet 4 Self adhesive Safety instructions 1 Installation...

Page 8: ...the associated dangers Instructions on how to install the slide rails are included in the Slide Rails Kit During the mounting procedure into a 19 industrial cabinet the KISS system must be powered dow...

Page 9: ...and to ensure accordance with regulations If the following General Safety Instructions are not observed it could lead to injuries to the operator and or damage to the product Unify Software and Soluti...

Page 10: ...the product Ensure that there is free and easy access to enable disconnection The product may only be opened for the insertion or removal of add on cards depending on the configuration of the system T...

Page 11: ...ush or pull the victim away from electrical contact Administer First Aid Immediately Call for Help First Aid Be familiar with basic first aid procedures for electrical shock A fundamental knowledge of...

Page 12: ...ce operations on this product Therefore always unplug all power cables and any other cables which provide external voltages before performing any work on this product Protective conductor PE connectio...

Page 13: ...ing to the manufacturer s instructions Do not dispose of lithium batteries in general trash collection Dispose of the battery according to the local regulations dealing with the disposal of these spec...

Page 14: ...roperly grounded tools and equipment Use antistatic mats antistatic wristband heel straps or air ionizers for more protection Always handle electrostatically sensitive components by their edge or by t...

Page 15: ...building must be conducted through an additional external lightning protection Lightning protection of this kind is known as additional primary protection The additional primary protection is guarante...

Page 16: ...connected to the OpenScape Branch 550 550HA The connection is made directly at the board Risk of electric shock through contact with live wires Use separate ground wires to provide protective groundin...

Page 17: ...formance of all those involved during the lifecycle of EEE All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities...

Page 18: ...88 x 355 mm 18 9 x 3 4 x 13 9 Weight up to 7 kg 15 3 lb Average Power Consumption 41W Rated Heat Emission 648 kJ h 614 2 BTU Operating Temperature 0 50 C 32 122 F Operating Humidity 10 93 40 C non con...

Page 19: ...ports cutouts on the rear side of the chassis Software Operating System MS Windows 10 IoT x64 Linux Ubuntu 1804 LTSB Desktop 64 bit BIOS AMI UEFI BIOS 5 x 1 2 2 OpenScape Branch 550 550HA models Tabl...

Page 20: ...st be ordered to support FXO FXS BRI E1 T1 Table 6 OpenScape Branch 550 550HA Performance OSB 550 OSB 550HA Models D44 A44 DP14 DP24 DP4 DP8 NC Max supported number of SIP registered lines1 500 500 50...

Page 21: ...NA Max number of concurrent integrated gateway calls 8 4 30 60 120 240 NA Number of Analog Terminal Adapter ports FXS 4 4 4 4 NA NA NA Max number of concurrent Voice Mail Calls 5 5 5 5 5 5 5 Max alloc...

Page 22: ...roduct only in or connected to systems that fulfill all necessary technical and specific environmental requirements This also applies to the operational temperature range of the specific product versi...

Page 23: ...or below another system 2 5 Hardware Characteristics OpenScape Branch 550 550HA is a scalable 2U rackmount system equipped with a micro ATX mainboard The flexible customer specific hardware system co...

Page 24: ...brackets for installation in a 19 Industrial rack Figure 1 OSB 550 550 HA front side 1 Power button 3 Unify logo 2 LED indicators 4 USB 2 0 ports Figure 2 Handle bracket with fastening screws 1 Chassi...

Page 25: ...the product is switched off The power button does not disconnect from the mains power supply When switched off using the power button there is still a standby voltage of 5 VSB on the mainboard AC Powe...

Page 26: ...on the front side Figure 4 LED indicators Table 7 Power LED and HDD LED activity description Power LED green LED illuminates green when the product is switched on by pressing the power button Prerequi...

Page 27: ...sitioning and number of interfaces varies depending on the system configuration Figure 5 Rear side of OSB 550 1 Input power socket 2 Power Supply Unit PSU ventilation holes 3 Mainboard external interf...

Page 28: ...ckets 2 Power Supply Unit PSU 3 Mainboard external interfaces 4 Rear side of the cover with three knurled screws 5 Slot brackets for Slots 1 2 gateway cards Slots 3 4 reserved no usage allowed 6 Cut o...

Page 29: ...d supplies the required internal 12V 5V and 3 3V voltages using standard certified cabling The OpenScape Branch 550 supports a 250W PSU with a nominal voltage range 100 V to 240 V OpenScape Branch 550...

Page 30: ...must be guaranteed using a separate cut off fixture Do not disconnect the power from the product while the product is switched on Performing a forced shut down may lead to loss of data or other undesi...

Page 31: ...rofile expansion cards 1 Cover retaining plate on the front side 2 Cover retaining plates on the rear side 3 Power Supply Unit PSU 4 Battery CR2032 5 Interface connectors available externally 6 Fasten...

Page 32: ...here are no ventilation holes on the top and bottom side of the product enabling installation directly on top of or below other systems in the 19 industrial rack cabinet Before installing read the ins...

Page 33: ...nstall the rubber feet as described in the instructions below to avoid scratching the installation surface Additionally observe the general instructions and any safety warnings within 1 5 1 General Sa...

Page 34: ...that the 19 Industrial rack cabinet is well ventilated and does not prevent the OpenScape Branch 550 from taking in air at the front and exhausting air at the rear Installing the OpenScape Branch 550...

Page 35: ...cket screw Figure 10 pos 6 3 4 How to Install and Remove a M 2 SSD Module To install an M 2 SSD module on the motherboard perform the following Locate the M 2 socket and the corresponding nut on the m...

Page 36: ...taring up observe the instructions in 1 5 Safety Information and read the instructions and warnings in this chapter Easy Access to Power Cable and Power Connectors The power cables must always remain...

Page 37: ...le to the corresponding sockets Input power socket Mains power supply socket using the electrical plug for the region Figure 11 Input power socket single AC power Figure 12 Input power socket Redundan...

Page 38: ...uctions Operation is permitted only with a functional fan assembly Replace a defective fan assemble only with an original fan assembly Fan assembly replaceable during operation Replace fan only by qua...

Page 39: ...Precautions and 1 5 5 Accessing Internal Components before replacing the lithium battery Danger of explosion when replaced with wrong battery type Replace only with the same or equivalent type recomm...

Page 40: ...r plug from the mains power source If it is necessary to store the product then re pack the product as originally delivered to avoid damage The storage facility must meet the products environmental st...

Page 41: ...V3 CFL Low Profile Legend Power Switch 2x System Fans External PCIe Slots External Controls LEDs External Connectors 2x Drive Bays Front access PSU Power LED SSD LED 2x USB 3 1 Gen 1 2x USB 3 1 Gen 2...

Page 42: ...E130 Series TE131 TE132 TE133 TE134 Sangoma card TE430 Series TE435B TE435 TE436B TE4364 Pin Signal Name Connector 1 Rx RJ45 Telco Port Connector 2 Rx 3 Not used 4 Tx 5 Tx 6 Not used 7 Not used 8 Not...

Page 43: ...4 F to 158 F Relative Humidity Operating and Storage Transit 10 93 40 C non condensing Environment Description Altitude Operating 5 000 m 16 400 ft Max Storage Transit 10 000 m 32 810 ft Max Shock Op...

Page 44: ...mperature Operating 0 C to 50 C 50 F to 122 F Storage Transit 20 C to 70 C 4 F to 158 F Relative Humidity Operating and Storage Transit 10 93 40 C non condensing Environment Description Vibration Oper...

Page 45: ...32 Electromagnetic compatibility of multimedia equipment Emission requirements EN 61000 6 3 Emission standard for residential commercial and light industrial environments Immunity Industrial Equipmen...

Page 46: ...use do not always apply as described or which may change as a result of further development of the products An obligation to provide the respective characteristics shall only exist if expressly agreed...

Reviews: