![Atos DHE FI Series Operating And Maintenance Information Download Page 6](http://html1.mh-extra.com/html/atos/dhe-fi-series/dhe-fi-series_operating-and-maintenance-information_3004832006.webp)
11/19
Maintenance must be carried out only by qualified personnel with a specific knowledge of hydraulics and electrohydraulics
• The valves does not require other maintenance operations except seals replacement
• Results of maintenance and inspection must be planned and documented
• Follow the maintenance instructions of the fluid manufacturer
• Any preventive maintenance should be performed only by experienced personnel authorized by Atos.
• Cleaning the external surfaces using a wet cloth to avoid accumulation of dust layer
• Don’t use compressed air for cleaning to avoid any dangerous dust dispersion on the surrounding atmosphere
• Any sudden increment in temperature requires the immediate stop of the system and the inspection of the relevant components
7.2 Repairing
In case of incorrect functioning or beak-down it is recommended to send the valve back to Atos or to Atos authorized service centers which
will provide for the reparation.
Unauthorized opening of the valves during the warranty period invalidates the warranty.
7.3 Transport
In order to prevent damage, the valves have to be transported in the original packaging or
with equivalent transport protection.
Observe the following guidelines for transportation of valves:
• before any movement check the valve weight reported in the relevant technical table
• use soft lifting belts to move or lift the heavy valves to avoid damages
WARNING
The valve may fall down and cause damage and injuries, if transported improperly.
Use personal protective equipment, such as: gloves, working shoes, safety goggles,
working clothes, etc.
7
MAINTENANCE
7.1 Ordinary maintenance
7.4 Storage
Valves are boxed using a VpCi protective packing system, offering best protection to oxidation during components sea transport or long
storage in humid environments.
The valve surface is protected with a zinc coating, which guarantees a corrosion resistance of over 200 hours in the salt spray test.
Additionally all valves are tested with mineral oil ISO VG 46; the oil film left after testing ensure the internal corrosion protection.
For the valves transporting and storing always observe the environmental conditions specified in the relevant technical tables.
Improper storage may damage the product.
The valves can be stored for up to 12 months under the following conditions:
• If there is no specific information in the components technical tables, comply with a storage temperature of –20 °C to +50 °C
• Do not store the valves outdoors
• Protect the valves against water and humidity in case of storage in open air
• Store the valves in the shelf or on a pallet
• Store the valves in the original packaging or comparable packaging in order to protect them from dust and dirt
• Remove the plastic covers from the valves mounting surface only before the assembly
In case of storage period longer than 12 months please contact our technical office