Industrial Managed
Ethernet Switch
User Manual
錯誤
!
使用
[
常用
]
索
引標籤將
Heading
1,Product Manual
套用到您想要在此處
顯示的文字。
Page
136
of
191
2.15.3 C
-
Ring
(
Compatible
-
Ring
)
Settings
Compatible
-
Ring
)
C
-
Ring
(
is similar to iA
-
Ring
.
The only difference is that it can be used for MOXA rings as well
.
For more information about this redundant ring protocol, please contact AtopTechnologies
.
Figure 2.152 shows how to set the Compatible
-
Ring
)
C
-
Ring
(
redundancy protocol
.
Note that the users should
disable
DIP Switch Control
as described in Section 2.3.13 and
ERPS
as described in Section 2.15.1 first in order
to enable
/
configure Compatible
-
Ring parameters on the web browser
.
Please follow the simple steps below based
on Figure 2.152 to setup the C
-
Ring
.
1. Enable the
C
-
Ring
by checking
Enabled
box
.
2. Select the
1
st
Ring Port
from the dropdown list
.
3. Select the
2
nd
Ring Port
from the dropdown list
.
4. Click on the
Update
button to save the change and allow the configuration to take effect
.
Note that the lower part of the C
-
Ring Setting webpage shows the
Status
of the C
-
Ring which provides its
State
,
1
st
Ring Port Status
and
2
nd
Ring Port Status
.
The description of the C
-
Ring setting is summarized in Table 2.54
Figure 2.152 Compatible
-
Ring (C
-
Ring) Setting Webpage
Table 2.54 Descriptions of Compatible-Ring Setting
Label
Description
Factory Default
C
-
Ring (Compatible-
Ring)
Enables Compatible-Ring or disable Compatible-Ring
.
Disabled
1
st
Ring Port
Selects the primary port for the Ring
.
Port7
2
nd
Ring Port
Selects the backup port for the Ring
.
Port8
2.15.4 U
-
Ring
This section enables the setup of U
-
Ring (Unicast Ring) on the managed switch. The U
-
Ring could provide
redundancy connection between two EH75XX industrial managed switches which are not directly connected by