Fig 25. Configuring E-mail Notification Parties : Web Configuration
One may configure the IP address of a mail server in your network. If your mail server requires an
authentication, check on “
My mail server requests authentication
” field and fill it the username and
password used for mail server authentication. The configuration is shown in Fig 26. Please contact your
network administrator for the IP address of the mail server and the username and password for
authentication.
Fig 26. Notification Mail Server Setting: Web Configuration
Alert Event
There are seven anomaly events (cold start, warm start, authentication failure, IP address changed,
password changed, LAN1 Link Down, and LAN2 Link Down) to trigger an alert event. You may select
which event(s) to be notified to the email list as previously configured, which event(s) to be logged onto
the SNMP Trap Server, and which event(s) to trigger a relay output to signal an external alarm as shown
in Fig 27.
Note that, before checking the “Trap” box, make sure a SNMP trap server is installed, and its address is
defined at “SNMP Trap Server” under “Network” configuration as shown in Fig 19.